INSTALLATION
Specification
15. Specification
15.1 Dimensions and connections
ESH 10 U-N Trend
296
c06
c01
200
100
c01
Cold water inlet
c06
DHW outlet
i13
Wall mounting bracket
ESH 10 O-N Trend
100
c06
c01
a20
www.stiebel-eltron.com
276
70
i13
ESH 10 U-N Trend
Male thread
Male thread
i13
70
a30
a10
Appliance
a20
Appliance
a30
Appliance
c01
Cold water inlet
c06
DHW outlet
i13
Wall mounting bracket
15.2 Wiring diagram
1/N/PE ~ 230 V
G 3/8 A
15.3 Heat-up diagram
G 3/8 A
The heat-up period depends on the degree of scaling and residual
heat. For the heat-up time for a cold water supply at 10 °C and a
maximum temperature setting, see the diagram.
25
20
15
10
5
0
35
40
45
x Temperature in °C
y Duration in min
Example:
Temperature setting = 65 °C
Heat-up time = approx. 18 minutes
15.4 Country-specific approvals and certifications
See the type plate for test symbols.
15.5 Extreme operating and fault conditions
In the case of faults, a peak temperature of up to 100 °C may briefly
occur in the system.
ESH 10 U-N Trend | ESH 10 O-N Trend |
ESH 10 O-N Trend
Height
mm
Width
mm
Depth
mm
Male thread
Male thread
Height
mm
Horizontal hole
mm
spacing
L N
50
55
60
65
70
75
80
506
296
276
G 1/2 A
G 1/2 A
386
200
85
19