INSTALLATION

Commissioning

9.3

Electrical connection

WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
When permanently connected to the power supply using
a dedicated junction box, the appliance must be able to
be isolated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
The voltage specified on the type plate must match the
mains voltage.
f Observe the type plate.
The following electrical connections are permissible:
Connection to a freely accessible standard
socket with matching plug
Permanent connection to an appliance junc-
tion box with earth conductor
10. Commissioning
WARNING Electrocution
Commissioning may only be carried out by a qualified
contractor in accordance with safety regulations.

10.1 Initial start-up

1.
f Either open the DHW valve of the tap or set the mono lever
mixer tap to "hot" until the water that flows out is free of air
bubbles.
f Insert the plug into the standard socket or set the fuse/MCB
in the distribution board.
f Select a temperature.
f Check the entire hydraulic installation for tightness.
Note
If you fail to follow the correct sequence (first water, then
power), the high limit safety cut-out will trip.
Proceed as follows:
f Disconnect the appliance from the power supply.
f Fill the appliance with water.
f Connect the appliance to the power supply.
www.stiebel-eltron.com
10.1.1 Appliance handover
f Explain the functions of the appliance to the user. Show the
f Make the user aware of potential dangers, especially the risk
f Hand over these instructions and, if applicable, the instruc-

10.2 Recommissioning

See chapter "Installation / Commissioning / Initial start-up".

11. Settings

11.1 Setting the temperature limit

ESH 10 U-N
ESH 10 O-N
Trend
Trend
X
X
X
X
The lever underneath the temperature selector allows you to limit
the setting range of the temperature selector to a specific maxi-
mum temperature.
f Turn the temperature selector to zero (fully anti-clockwise to
f Pull off the temperature selector.
f Adjust the lever to the required maximum temperature.
f Install the temperature selector set to zero (•

12. Appliance shutdown

f Isolate the appliance from the power supply by removing the
2.
f Drain the appliance (see chapter "Installation / Maintenance /

13. Troubleshooting

user how to operate the appliance.
of scalding.
tions for any accessories.
"•").
plug or by tripping the MCB in the distribution board.
Draining the appliance").
fault
Cause
The appliance
The appliance was not filled
does not supply
with water before being
hot water.
connected to the power
supply. The correct com-
missioning sequence was
not observed. The high limit
safety cut-out has tripped.
The high limit safety cut-out
has tripped.
Loud boiling
The appliance is scaled up. Descale the appliance.
noises inside
the appliance.
ESH 10 U-N Trend | ESH 10 O-N Trend |
).
remedy
Pull the plug from the power
socket. Fill the appliance with
water. Re-insert the plug into
the standard socket (see chap-
ter "Installation / Commission-
ing").
Remedy the cause of the fault.
If necessary, replace the tem-
perature controller. Allow the
appliance to cool down. If you
have isolated the appliance
from the power supply, the high
limit safety cut-out will be reset
automatically.