Download Inhoudsopgave Inhoud Print deze pagina

Test Symbols; Appliance Description; Operation; Cleaning, Care And Maintenance - Stiebel Eltron ESH 10 U-N Trend Instructies Voor Gebruik En Installatie

Open drukloze kleine warmwater
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 32

OPErATION

Appliance description

Material losses
!
The user should protect the appliance and its tap against
frost.
Material losses
!
Never subject the appliance to water pressure. The tap
outlet has a vent function. Scale build-up can block the
outlet and subject the appliance to pressure.
f Never seal the tap outlet.
f Only use special aerators for non-pressurised water
heaters.
f Never extend the tap outlet with a hose.
Material losses
!
Connecting the appliance via a time switch will cause an
unintentional reset of the high limit safety cut-out.
f Never connect the appliance to the power supply via
a time switch.
2.3

Test symbols

See type plate on the appliance.
3.
Appliance description
This open vented (non-pressurised) appliance constantly main-
tains the water content at the pre-selected temperature. During
heating, expansion water drips from the tap. The appliance may
only be installed with taps for open vented (non-pressurised)
water heaters (see chapter "Installation / Appliance description /
Accessories").
Subject to season, varying cold water temperatures can result in
different maximum amounts of mixed outlet water.
Thermostop function
The thermostop function (thermal separation) of the
ESH 10 U-N Trend prevents the tap becoming hot in standby mode.
3.1
Operation
You can set any required DHW outlet temperature variably at the
temperature selector. The heat-up indicator illuminates during
the heat-up process.
ESH 10 U-N Trend
1
2
1 Heat-up indicator
2 Temperature selector
14
| ESH 10 U-N Trend | ESH 10 O-N Trend
ESH 10 O-N Trend
2
1
Depending on the system, the actual temperatures may vary from
the set value.
Cold. On this setting, the appliance is protected from frost.
The tap and the water line are not protected.
E
Approx. 40 °C
e
Recommended energy saving setting (approx. 60 °C),
minor scaling
Note
A qualified contractor can set a temperature limit on the
appliance (see chapter "Installation / Settings / Setting
the temperature limit").
4.

Cleaning, care and maintenance

f Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
f Check the tap regularly. You can remove limescale depos-
its at the tap outlet using commercially available descaling
agents.
Almost every type of water will deposit limescale at high temper-
atures. This settles inside the appliance and affects both perfor-
mance and service life. The heating elements should therefore be
descaled if necessary. A qualified contractor who is aware of the
local water quality will tell you when the next descaling is due.
5.

Troubleshooting

Problem
Cause
The appliance does not
The temperature selector
supply hot water.
is set to "
No power at the appli-
ance.
Water can only be drawn
The aerator in the tap is
at a reduced rate.
scaled up.
Loud boiling noises in-
The appliance is scaled
side the appliance.
up.
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000).
remedy
Switch the appliance ON
by turning the tempera-
".
ture selector.
Check the plug / fuses in
the distribution board.
Descale / replace the
aerator.
Have the appliance
descaled by a qualified
contractor.
www.stiebel-eltron.com

Advertenties