PROBLEM
Motor starts but shuts off
soon after
The motor gets hot and
shuts off periodically
No power to controller
Dry Contacts not working
6.2 Fault Codes
FAULT
E21
Software Overcurrent
E22
DC Overvoltage
E23
DC Undervoltage
E26
Hardware Overcurrent
E2A
Stall fault
E2D
Processor - Fatalt
E2E
IGBT Overtemperature
E2F
Loss of Phase
E31
Processor - Registers
Installation and general maintenance manual
SOLUTION
•
Check for debris stuck between impeller and diffuser.
•
Have a certified professional check to see if the drive shaft is seized with all power
off.
•
If large amounts of debris are found, check your strainer basket for breaks. Replace
the strainer basket if necessary
•
Ensure adequate room around motor for air circulation to keep motor cool.
•
Have a qualified electrician check for loose connections and check voltage at
motor while in operation. Main voltage outside of 10% of motor rating plate may
cause motor to experience excessive loads.
•
Have a certified electrician test voltage on RS-485 line while power is available to
motor. It should be between 8 and 12 Volts DC between pins 1 and 4.
•
Check RS-485 connector wiring (pins 1-4 should be Red, Black, Yellow, Green).
•
Test motor drive with RS-485 jumper method: Using small sections of 22 AWG
wire, jump pins 1 to 3 and 2 to 4. Re-install connector and attach access cover.
Apply power to motor to see if motor spins at 2600 RPM indefinitely. If motor
works, the issue is with the RS-485 line or controller.
•
Check low voltage wiring for breaks between motor and external switches. With
all power off, use a multimeter to check continuity of each low voltage lines from
motor to controlle. Replace the dry contact wires completely if necessary.
ACTIONS
Cycle power to the motor
Ensure input voltage is in the correct range
Ensure input voltage is in the correct range
Cycle power to the motor
Check pump, impeller and motor fan for obstructions, then
cycle power to motor
Contact your local pool service professional
Wait for temperature of the motor to cool down. Ensure
motor is clear of obstructions that limit proper ventilation
Contact your local pool service professional
Contact your local pool service professional
- VARIABLE SPEED PUMP
.
39