PUMP ABOVE WATER LEVEL
1. Open the air relief valve on the filter.
2. Remove the pump lid and fill the basket with water.
3. Check for debris around the lid o-ring seat before replacing the lid.
4. Tighten the lid by verifying the "locked" indicators on the lid are aligned with the pump's ports.
Hand tighten only, do not use tools. Make sure all valves are open and the pump unions are
tight.
5. Restore power to the pump and start the pump.
6. Once the pump has primed and water comes out of the air relief valve on the filter, close the air
relief valve and inspect the system for any leaks.
NOTE
All pumps in this manual are NSF-certified as being able to prime at heights up to 3m
above the pool water level, at sea level. However, to achieve better self-priming, install
the pump as close as possible to the water level of the pool.

4.2 OPERATIONAL CONTROLS

Due to an undervoltage protection placed in the software to protect the internal electronics,
there may be an error during motor startup. If this situation occurs, simply let the motor sit
without power for approximately 3-5 minutes to allow the capacitors to completely drain before
restarting the motor.
*NOTE: Symbols flash during set up process.
Clock turns On during AUTO mode and Off during
MAN mode. Wi-Fi turns On when connected.
FIGURE 8 - NORMAL OPERATION MODE CONTROLS
NOTE
If power is removed, motor will return to the last speed selected when power is restored.
Motor will remember ON/OFF states. If there is a fault, Error LED will blink and display
will show an error number. See Section 6 more information on fault codes.
Pump Functions
Display Lock/Unlock - Press
"uLoc".
Pump Power ON/OFF - Press
Speed Selection - Low/Medium/High (Press
34
IMPORTANT
• On/Off (Press for 2 seconds)
• Back or Exit
• Browse down
• Adjust value down
MODE
• Browse up
SET
• Adjust value up
• Manual/Auto (Press for 2 seconds)
MODE
• Enter in Settings mode or Confirm action
SET
and
simultaneously for 2 seconds. Display will show "Loc" or
MODE
SET
MODE
SET
for 2 seconds.
or
in Manual Mode)
MODE
SET
MODE
MODE
SET
SET
Installation and general maintenance manual
*Pump Speeds
(Low/Med/High)
T
START
*Pump
T
STOP
Start/Stop
*Clock
Settings
*Wi-Fi
- VARIABLE SPEED PUMP

Advertenties

Inhoudsopgave
loading

Inhoudsopgave