IMPORTANT SAFETY, INSTALLATION, AND MAINTENANCE
INFORMATION
This instruction manual contains basic information on the safety measures to be adopted
during installation, maintenance and start-up. The fitter and the user must therefore read
the instructions before installation and start-up.
The manual can be downloaded as a PDF file from the website: www.zodiac-poolcare.com
•
The units described in this Manual are specially designed for the pre-filtering and
recirculation of water in swimming pools.
•
They are designed to work with clean water at temperatures that do not exceed 35 ºC.
•
All assembly, electrical installation and maintenance work must be carried out by
qualified, authorized personnel who have carefully read the installation and service
instructions.
•
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play
with the appliance.
•
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
•
Our pumps may only be assembled and installed in pools that are compliant with
standards IEC / HD 60364-7-702 and required national rules. Should you have any doubts
please consult your dealer.
•
The installation should follow standard IEC/HD 60364-7-702 and required national rules
for swimming pools.
•
The pump can not be installed in the Zone 0 and Zone 1. To see drawing refer to page 7.
•
The pump is intended to be used while fastened to a support or while secured in a specific
location in a horizontal position.
•
See the maximum pump pressure (H max), in meters in page 5.
•
A sump with an adequate outlet for the liquid is considered to be placed where flooding is
likely to occur.
•
If a self-priming pump is to be fitted above the water level, the pressure differential to
the pump suction pipe should not be higher than 0.015 MPa (1,5 mH2O). Ensure that the
suction pipe is as short as possible as a longer pipe would increase suction time and the
installation's load losses.
22
Installation and general maintenance manual
- VARIABLE SPEED PUMP