Operation
CDF18
Battery monitor mode
Switch-off voltage at 12 V
Restart voltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
CDF26, CDF36, CDF46
Battery monitor mode
Switch-off voltage at 12 V
Restart voltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
I
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode "HIGH". If the cooler is connected to a supply battery,
the battery monitor mode "LOW" will suffice.
If you wish to operate the cooler from the AC mains, set the battery
monitor to the "LOW" position.
CDF26: Setting the battery monitor mode
This is how to select the battery monitor mode:
1. Switch on the cooler.
2. Press the "SET" button three times.
3. Use the "+" and "–" buttons to select the battery monitor mode.
✔ The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
CDF36, CDF46: Setting the battery monitor mode
This is how to select the battery monitor mode:
1. Switch on the cooler.
14
LOW
10.2 V ± 0.3 V
11.2 V ± 0.3 V
22.0 V ± 0.3 V
23.3 V ± 0.3 V
LOW
MED
10.1 V
11.4 V
11.1 V
12.2 V
21.5 V
24.1 V
23.0 V
25.3 V
CDF
HIGH
11.2 V ± 0.3 V
12.2 V ± 0.3 V
23.9 V ± 0.3 V
25.1 V ± 0.3 V
HIGH
11.8 V
12.6 V
24.6 V
26.2 V