Parameter
Vaste br temp. minimum
Vaste br temp. stijging
Vaste br diff. AAN
Vaste br diff. UIT
Pvast br toerenta minimum
Collect. temp. stijging
Multi-externe uitgang
Dag/Tijdstip
Inbedrijfstellingsprotocol van de instelbare parameters "Opties" (invullen a.u.b.)
Parameter
Collectorbeveiliging
Volume-impulsteller
Collect. vertrek voeler
Starthulp collect.
Zwernbad oplading
Fabrieksinstel. nehmen
Instelbereik
20°C...90°C
0 K/min...40 K/min
0 K...40 K
0 K...40 K
10%...100%
0,0...10 K/Min
0...12
Ma. 00:00...Zo 23:59
Instelbereik
0 ... 95
Ja/Neen
Ja/Neen
Ja / Neen
Ja / Neen
Ja / Neen
Voorinstelling
50°C
0 K/min
15 K
5 K
30%
1,5 K/Min
8
Voorinstelling
0
Neen
Neen
Neen
Ja
Neen
B
Ingesteld
[________]
[________]
[________]
[________]
[________]
[________]
[________]
[________]
Ingesteld
[________]
[________]
[________]
[________]
[________]
[________]
95