Putting into operation
This can occur only after having performed, with positive results, all the inspec-
tion phases of the gear motor and other devices present. To put it into opera-
tion refer to the instructions manual of the control unit.
IMPORTANT – It is forbidden to put into partial or provisional operation.
6
PRODUCT MAINTENANCE
To keep the level of safety consistent and to guarantee maximum life of the
entire automation it is necessary to maintain it regularly.
The maintenance must be performed in line with the safety instructions of this
manual and according to what is set out by the laws and regulations in force.
For the gear motor a programmed maintenance within no more than 6 months
is required.
Maintenance operations:
01. Disconnect any sources of electricity.
02. Check the status of deterioration of all the materials which make up the
automation with particular attention to signs of erosion or oxidation of the
structural parts: replace the parts which do not provide sufficient guaran-
tees.
03. Check the screw connections are sufficiently tight.
04. Check the bolt and endless screw are suitably greased.
05. Check the wear of the moving parts and, if necessary, replace used parts.
06. Reconnect the sources of electrical power and perform all the tests and
checks envisaged in chapter 5.
For the other devices present in the system refer to the individual instruction
manuals.
CAUTIONS: • The technical features set out refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to make alterations to the product
any time it deems it necessary, keeping the same functionality and destination of use.
Type
Power input
Maximum absorption
Nominal absorption
Maximum absorbed power
Nominal absorbed power
Protection grade
Travel
Speed loadless
Speed loaded
Maximum thrust
Nominal thrust
Operating temperature
Cycles h at nominal torque
Durability
Insulation class
Dimensions (mm)
Weight (kg)
TECHNICAL FEATURES OF THE PRODUCT
WG4024
WG5024
electromechanical gear motor for gates or doors with leaf opening
24 V
24 V
3,5 A
3,5 A
2 A
2 A
85 W
85 W
50 W
50 W
IP 44
IP 44
320 mm
460 mm
0,018 m/s
0,016 m/s
0,013 m/s
0,012 m/s
1500 N
1500 N
500 N
500 N
40
40
estimated between 80,000 and 250,000 cycles of manoeuvres according to the conditions set out in Table 2
A
A
770 x 98 x 95 h
920 x 98 x 95 h
6
6
DISPOSAL OF THE PRODUCT
This product is an integral part of the automation, and therefore, they
must be disposed of together.
As for the installation operations, at the end of the life of this product, the dis-
mantling operations must be performed by qualified personnel.
This product is made from different types of materials: some can be recycled,
others must be disposed of. Please inform yourselves on the recycling or dis-
posal systems provided for by the laws in force in your area, for this category of
product.
CAUTION! – some parts of the product can contain polluting or dangerous
substances which, if dispersed in the environment, may cause serious harm to
the environment and human health.
As indicated by the symbol at the side, it is forbidden to throw
this product into domestic refuse. Therefore, follow the "sepa-
rated collection" instructions for disposal, according to the
methods provided for by local regulations in force, or redeliver
the product to the retailer at the moment of purchase of a new,
equivalent product.
CAUTION! – the regulations in force at local level may envisage heavy sanc-
tions in case of abusive disposal of this product.
WG4000
WG4000/V1
230 V ~ 50 Hz
120 V ~ 60 Hz
1,5 A
1,5 A
0,5 A
0,5 A
200 W
200 W
130 W
130 W
IP 44
IP 44
320 mm
320 mm
0,016 m/s
0,020 m/s
0,012 m/s
0,015 m/s
1500 N
1500 N
500 N
500 N
-20 °C to +50 °C
30
30
F
F
770 x 98 x 95 h
770 x 98 x 95 h
6
6
WG5000
WG5000/V1
230 V ~ 50 Hz
120 V ~ 60 Hz
1,5 A
2,5 A
0,5 A
1 A
200 W
200 W
130 W
130 W
IP 44
IP 44
460 mm
460 mm
0,013 m/s
0,016 m/s
0,010 m/s
0,012 m/s
1700 N
1700 N
600 N
600 N
30
30
F
F
920 x 98 x 95 h
920 x 98 x 95 h
6
6
English – 3