FC 300 Programmeerhandleiding
[35]
Digitale ingang DI27
[36]
Digitale ingang DI29
(alleen FC 302)
[37]
Digitale ingang DI32
[38]
Digitale ingang DI33
[39]
Startcommando
[40]
Omv. gestopt
[41]
Reset uitsch.
[42]
Autoreset uitsch.
[43]
Toets OK
[44]
Toets Reset
[45]
Toets links
[46]
Toets rechts
[47]
Toets omhoog
[48]
Toets omlaag
[50]
Comparator 4
[51]
Comparator 5
[60]
Log. regel 4
[61]
Log. regel 5
[70]
SL time-out 3
[71]
SL time-out 4
[72]
SL time-out 5
[73]
SL time-out 6
[74]
SL time-out 7
13-43 Logische regel operator 2
Array [6]
*
UITGESCH.
[0]
[1]
AND
[2]
OR
[3]
AND NOT
[4]
OR NOT
[5]
NOT AND
[6]
NOT OR
[7]
NOT AND NOT
[8]
NOT OR NOT
13-44 Logische regel Boolean 3
Array [6]
[0]
FALSE
[1]
TRUE
Selecteer de tweede booleaanse ingang (TRUE of FALSE) voor de geselecteerde logische regel. Zie par. 13-01
Gebeurt. starten
([0] - [61]) en par. 13-02
Selecteer de tweede logische operator die moet worden gebruikt bij de booleaanse ingang die wordt berekend
in par. 13-40, 13-41 en 13-42 en de booleaanse ingang van par. 13-42.
[13-44] staat voor de booleaanse ingang van par. 13-44.
[13-40/13-42] staat voor de booleaanse ingang berekend in par. 13-40, 13-41 en 13-42. UITGESCH. [0] (fa-
brieksinstelling). Selecteer deze optie om par. 13-44 te negeren.
Evalueert de uitdrukking [13-40/13-42] AND [13-44].
Evalueert de uitdrukking [13-40/13-42] OR [13-44].
Evalueert de uitdrukking [13-40/13-42] AND NOT [13-44].
Evalueert de uitdrukking [13-40/13-42] OR NOT [13-44].
Evalueert de uitdrukking NOT [13-40/13-42] AND [13-44].
Evalueert de uitdrukking NOT [13-40/13-42] OR [13-44].
Evalueert de uitdrukking NOT [13-40/13-42] AND NOT [13-44].
Evalueert de uitdrukking NOT [13-40/13-42] OR NOT [13-44].
®
MG.33.M3.10 – VLT
is een geregistreerd handelsmerk van Danfoss
Gebeurt. stoppen
([70] - [74]) voor meer informatie.
2. Programmeren
2
137