Keep all the hose connections clean. Open both condensation screw plugs
from time to time (Fig. 1 (34)) to drain condensation from the compressed air
tank (Fig. 1 (35)), especially necessary when working at low temperatures;
observe storage temperature for unit of ≥ 5°C (1.3).
Remove the protective hood for the following maintenance work. Loosen the
6 screws of the protective hood (Fig. 1 (37)) for this. Empty the tank of the
condensation and particle fi lter (Fig. 1 (46)) in the electronic fl ushing and
pressure testing unit with compressor regularly. The fi lter cartridge must
be cleaned and replaced if necessary. Clean the air fi lter of the compressor
regularly.
Change the fi ne fi lter cartridge (Art. No. 043054) of the fi ne fi lter (Art. No.
115609) regularly.
In order to ensure that the date and time remain saved at all times, the button
cell (Lithium CR1220, 3 V) on the back of the operating panel (Fig. 1 (36))
should be changed about every two years. Loosen the 6 screws of the protec-
tive hood (Fig. 1 (37)) to do this, remove the protective hood. Then loosen the
4 screws of the operating panel and change the button cell on the back of the
operating panel.
Clean the machine regularly especially when it has not been in use for a long
time. Clean plastic parts (e.g. housing) only with REMS CleanM machine cleaner
(Art. No. 140119) or a mild soap and a damp cloth. Do not use household
cleaners. These often contain chemicals which can damage the plastic parts.
Never use petrol, turpentine, thinner or similar products for cleaning.
5 Fault
NOTICE
If faults occur, fi rst check whether the respective latest version software (Ver. Software) is installed on the input and control unit. Select the Settings menu and then
Device data to display the version software. The latest version software (Ver. Software) for the input and control unit is available by USB stick as a download under
www.rems.de → Downloads → Software. Compare the number of the version software with the latest version software number and install the latest version software
on the input and control unit by means of a USB stick if necessary. See 2.3 for the further procedure.
If the REMS Multi-Push welcome message remains constant in the control panel (Fig. 1 (36)) or if the Error message is displayed in any program on the control
panel (36), the power supply of REMS Multi-Push should be interrupted by pulling out the mains plug or pressing the RESET button (2) and switched back on
according to 2.1 Electrical Connection. If Error is displayed again, the procedure must be repeated after pressure in the REMS Multi-Push has been relieved.
To do this, pull out the mains plug, close the water pipe and remove all the hoses, caps and stoppers from the REMS Multi-Push, then switch back on according
to 2.1 Electrical Connection of Machine.
5.1 Fault: REMS Multi-Push does not switch on after pressing the On/Off button (4).
Cause:
● On/Off button (Fig. 2 (4)) pressed too briefl y.
● PRCD fault current circuit breaker (Fig. 1 (1)) is not switched on.
● Mains lead/PRCD defective.
● REMS Multi-Push defective.
5.2 Fault: Compressor will not start although there is low or no pressure in the compressed air tank (see the display on the compressed air tank pressure gauge
(Fig.4 (30)).
Cause:
● Compressor emergency stop button (Fig.4 (29)) is switched off.
● REMS Multi-Push defective.
5.3 Fault: The necessary minimum fl ow velocity is not achieved in the fl ushing program.
Cause:
● Stop tap of the house connection is only partly open.
● Fine fi lter (Fig. 3 (12)) is contaminated.
● Not enough tapping points opened.
● Hoses connected incorrectly.
● Wrong defaults entered.
● Valves blocked, considerable, irremovable encrustations in the pipes.
5.4 Fault: The set pressure (p refer) is not reached in the test with compressed air or compressed air pump programs.
Cause:
● Installation or compressed air hose (Fig. 4 (23)) leaking.
● No or too little pressure in the compressed air tank.
● REMS Multi-Push defective.
5.5 Fault: The set pressure (p refer) is not established in the test with water program (Multi-Push SLW).
Cause:
● The water pressure of the house connection is greater than the set pressure
(p refer).
● Suction/pressure hose (Fig. 1 (13)) or high-pressure hose (Fig. 4 (26)) leaking. ● Change suction/pressure hose or high-pressure hose.
● Hydro-pneumatic pump does not build up pressure.
● Stop tap of the water supply is closed or only partly open.
● No or too little air pressure in the compressed air tank.
● REMS Multi-Push defective.
Make sure that liquids cannot get inside the electronic fl ushing and pressure
testing unit with compressor.
4.2 Pressure gauge calibration
Calibration of the control elements (pressure sensors) of the REMS Multi-Push
is not necessary. It is recommended to check the pressure gauge every 2 years.
To do this, the pressures shown in the display can be checked by additionally
connecting an accurate, fi nely scaled pressure gauge (see Accessories 1.2)
between REMS Multi-Push and the installation. You must make sure here that
the pressure of the stress test is not applied to the fi nely scaled pressure gauge
up to 250 mbar, otherwise it will be destroyed.
The pressures displayed on the screen of the REMS Multi-Push can be calibrated
at the REMS-ROLLER Service Center if necessary. A test certifi cate is issued
for the calibration. Calibration of the external pressure gauge for the pressurised
vessel (30) and the compressed air tools (32) is not necessary.
4.3 Inspection / Repair
WARNING
Pull out the mains plug before carrying out maintenance or repair work!
This work may only be performed by qualifi ed personnel.
Remedy:
● Press On/Off button for about 2 s, then release.
● Switch on PRCD fault current circuit breaker as described in 2.1..
● Have the mains lead/PRCD changed by qualifi ed personnel or an authorised
REMS customer service workshop.
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.
Remedy:
● Switch on compressor by pulling out the emergency stop button.
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.
Remedy:
● Fully open the stop tap.
● Clean or change the fi ne fi lter and fi lter cartridge.
● Open the appropriate number of tapping points.
● Connect hoses as shown in Fig. 3.
● Check defaults, correct if necessary. Restart the program.
● Clean/change valve(s). Clear encrustations.
Remedy:
● Check installation for leaks. Change the compressed air hose.
● See 5.2 Fault:
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.
Remedy:
● Close the shut-off valve of the house connection.
● Connect suction/pressure hose between the house connection and the
pressure test with water supply, see 2.6.2.
● Fully open the stop tap.
● Hydro-pneumatic pump requires compressed air, see 5.2 Fault:
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.