descrIptIon of unIt
Before start with the backfitting, pull of main
plug of socket, disassemble suction system
and high pressure hose
3.6

tecHnIcAl dAtA FInISH 250

Voltage :
Fuses :
Unit connecting line :
Max. current consumption
hose heating :
Degree of protection :
Acceptance capacity :
Max. operating pressure :
Max. volume flow :
Volume flow at 12 MPa
(120 bar) with water :
Max. temperature of the
coating material :
Max. viscosity :
Empty weight pump :
Hydraulic oil filling
quantity :
Max. vibration at the spraygun
:
Max. sound pressure level:
*Place of measurement: 1 m distance from unit and 1.60
m above floor, 12 Mpa (120 bar) operating pressure,
reverberant floor
38
All manuals and user guides at all-guides.com
1
230 V AC, 50 Hz
16 A time-lag
4 m long, 3 x 1.5 mm²
4,6 A
IP 54
1,1 kW
25 MPa (250 bar)
2.2 l/min
1.8 l/min
43 °C
15,000 mPas
28 kg
0.65 liter
lower than 2.5 m/s²
74 dB (A)*
3.7

tecHnIcAl dAtA FInISH 270

Voltage :
Fuses :
Unit connecting line :
Max. current consumption
hose heating :
Degree of protection :
Acceptance capacity :
Max. operating pressure :
Max. volume flow :
Volume flow at 12 MPa
(120 bar) with water :
Max. temperature of the
coating material :
Max. viscosity :
Empty weight pump :
Hydraulic oil filling
quantity :
Max. vibration at the spraygun
:
Max. sound pressure level:
*Place of measurement: 1 m distance from unit and 1.60
m above floor, 12 Mpa (120 bar) operating pressure,
reverberant floor
Finish 270 / 250
230 V AC, 50 Hz
16 A time-lag
4 m long, 3 x 1.5 mm²
6.0 A
IP 54
1.3 kW
25 MPa (250 bar)
2.9 l/min
2.3 l/min
43 °C
15,000 mPas
29.5 kg
0.65 liter
lower than 2.5 m/s²
74 dB (A)*

Advertenties