Operation: Activate the start/stop procedure by holding the charging card
or charging key in front of the scanner. You will hear a single acoustic signal
and the light will blink green.
With type 2 sockets, the inserted plug is locked into the charging socket.
Subsequently, the charging station communicates with the vehicle and
the BackOffice system. Once all safety and payment regulations have been
checked, the maximum allowed charging current is listed.
The charging procedure starts automatically and the light turns blue. (Other
options are possible).
To stop the charging procedure, hold your card in front of the scanner.
You will hear two acoustic signals, the light will blink green and the plug is
unlocked. You can now remove the plug.
The push button/auto-start operation replaces the scanner and charging
card/charging key and does not require BackOffice verification.
21. TECHNICAL SPECIFICATIONS
Number of charging points:
Connections:
Power output per socket:
Connection value:
Protocol:
Positioning:
Communication:
Casing material:
Standard colour::
Treatment:
Casing dimensions HxWxD:
Weight:
Operating/ambient temperature::
Water resistance:
Vandalism resistance:
Wall mounting:
2
Type 2
Max. 22 Kw
from 1 x 16A to 3 x 63A
Mode 3
GPS
UMTS / GSM Modem / Controller
with RFID-reader
3.7mm steel
RAL6018/ RAL9016
Anti-corrosion and powder coating
800mm x 220mm x 200mm
21 kg
-25°- to 60°
IP54
IK10
4x 12 mm mounting holes in wall
adapter-plate including mounting
material
19