5.16 Settings menu: Call Installer menu

Menu only accessible for well trained installers. Do not change settings injudiciously.
Pin code: 5050
To call the Installer menu you follow the image below:
back to main screen
2x
ESC
Settings
Summer/wintertime
Information
PIN
Factory menu
Installer menu
select
In the settings menu select Installer menu and then push the OK button.
Now enter the Pin code for the Installer menu. With the  and  button, change the first
figure and confirm this by pushing the OK button, the display automatically jumps to the
next figure. Change all desired figures in that way. After the 4th figure, when the pin code
has been correctly entered, the service menu is displayed on the screen.
Burner check
Possibility of checking the ionizing current of the of the unit concerned.
Self learning heating
To read out the Self Learning Heating.
Possibility to manually set the Self Learning Heating to a fixed value.
Possiblity to set the minimum time of which the unit must be in operation during the heating
curve.
Room Controller
Setting P band
Setting I time
Hysteresis UP: maximum temperature exceedance of the desired temperature at which the unit
stays in operation.
Hysteresis DOWN: maximum temperature deviation lower than the desired temperature, at
which the unit must come back into operation.
Supply temp max: maximum supply temperature of the unit
Supply temp min: minimum supply temperature of the unit
Clock correction
Correction if the clock keeps deviating.
Setting:
ppm -1...-120
ppm +1...+120
ESC
Installer menu
Code
0 0 0 0
OK
factory default
Installer menu code
5 0 5 0
select
OK
to next digit
Correction if clock is always ahead
Correction if clock keeps running behind
ESC
Installer menu
Control On/Off
OK