15.1 Normal operation
With the normal operating mode you
can determine settings yourself such as
the degree of air humidity that should
be reached in the space and the exhaust
stage.
If the air humidity in the space exceeds
the set value the
dehumidifier will begin the
dehumidifying function. As soon as the
set air humidity is reached, the
dehumidifying function is switched off
while the exhaust will still run for
approx. 3 minutes to prevent
overheating of the dehumidifier or of
the compressor and then switches off as
well. The control light above button 19
indicates that the desired air humidity
was reached (see fig. C)
As soon as the air humidity in the space
rises above the set value, the
dehumidifying function is
re-activated and the exhaust runs in the
set exhaust stage.
Setting options:
-
- 30% to 80% air humidity (in
five-per cent increments)
-
CO (desired air humidity of under
30% during continuous air
dehumidification)
-
- low exhaust stage
-
+ high exhaust stage
Proceed as follows when setting the
normal operating mode:
1. Press button 22, until the control
light above button 22 blinks for
normal operation.
2. The control light blinks for a few
seconds. As soon as the control light
is constantly on, the dehumidifier
works in the normal operating mode.
3. Press the + button in order to
increase the desired air humidity or
press the - button in order to reduce
the desired air humidity.
4. The selected air humidity blinks for a
few seconds.
5. Subsequently, the display on the
screen changes to the current air
humidity.
6. Press button 20 in order to select
the desired exhaust stage.
7. Control light 10 or 22 will indicate
which exhaust stage you have set.
8. Press button 23 in order to select
another operating mode and to
terminate the normal operating
mode.
15.2 Drying laundry
In the laundry drying operating mode
the degree of air humidity (CO) and the
high exhaust stage are pre-set and
cannot be changed. You can select this
operating mode for example to guide
the air flow with dehumidified air via the
exhaust flap (1) to laundry which is to
be dried.
1. Press button 23, until the control
light (13) for drying laundry blinks
(see fig. C). The control light will
blink for a few seconds.
2. As soon as the control light is
constantly on, the dehumidifier
works in the laundry drying mode.
3. Control light 10 indicates that the
high exhaust stage is set.
4. The current air humidity is indicated
in the display.
5. Press button 23 in order to select
another operating mode and to
terminate the laundry drying
operating mode.
15.3 Air circulation
In the air circulation operating mode
only the selected exhaust stage is active
whereas the dehumidifying function is
de-activated. For example, you can
select this operating mode
in order to let the room air circulate,
without dehumidifying it.
1. Press button 19 until the control
light above button 19 blinks for air
circulation (see fig. C). The control
light will blink for a few seconds.
2. As soon as the control light is
constantly on, the dehumidifier will
work in the air circulation mode. The
current air humidity is indicated in
the display.
3. Press button 20 in order to select
the desired exhaust stage.
4. Control light 11 or 20 will indicate
which exhaust stage you have set.
Page | 25