Download Inhoudsopgave Inhoud Print deze pagina

Voedingschakeling En Bekabelinguitvoering; Algemeen - Daikin RSEYP16KJY1 Installatiehandleiding

Met vrv systeem
Inhoudsopgave

Advertenties

RSEYP24,26,28,30
A1P...............................Printplaat (MAIN)
A2P...............................Printplaat (INV)
A3P ,4P ..........................Printplaat (SUB)
A5P...............................Printplaat
BS1-5 ............................ Druktoetsschakelaar (MODE, SET, RETURN,
BEDRADING CHECK, RESET)
C11R,12R.....................Condensator
C21R,22R.....................Condensator
C3R,4R.........................Condensator
C5,6..............................Condensator
X70A,X71A...................Connector
F1S...............................Overspanningsbeveiliging
F2C,3C .........................Stroombeveiligingsrelais (M2C,3C)
F1U,2U .........................Zekering (250V,10A) (A1P)
F1U...............................Zekering (250V,10A) (A3P ,4P)
H1P-7P ......................... Verklikkerlamp (onderhoudsmonitor - oranje)
(A1P)
H2P ; Voorbereiden - knipperend, Bij storing -
brandend
Malfunction detection-light up
H1P-4P ......................... Verklikkerlamp (onderhoudsmonitor - rood)
(A2P)
HAP............................... Verklikkerlamp (onderhoudsmonitor - groen)
(A1P-4P)
INV ...............................Gelijkstroom - wisselstroomomzetter
E1HC-3C ......................Carterverwarming
K1M-3M........................Magneetcontact (M1C,2C,3C)
K1R ..............................Magnetisch relais (M11F) (A1P)
K1R ..............................Magnetisch relais (A2P)
K2R ..............................Magnetisch relais (M11F) (A1P)
K2R ..............................Magnetisch relais (K1M) (A2P)
K3R ..............................Magnetisch relais (M12F) (A1P)
K4R ..............................Magnetisch relais (K2M) (A1P)
K5R ..............................Magnetisch relais (K3M) (A1P)
K5R ..............................Magnetisch relais (A3P ,A4P)
K6R ..............................Magnetisch relais (E1HC) (A1P)
K6R ..............................Magnetisch relais (M21F) (A3P)
K6R ..............................Magnetisch relais (M3F) (A4P)
K7R ..............................Magnetisch relais (Y1R) (A1P)
K7R ..............................Magnetisch relais (M22F) (A3P)
K7R ..............................Magnetisch relais (M4F) (A4P)
K1R ..............................Magnetisch relais (Y4S) (A3P)
K2R ..............................Magnetisch relais (Y5S) (A3P)
K3R ..............................Magnetisch relais (Y6S) (A3P)
K4R ..............................Magnetisch relais (Y7S) (A3P)
K8R ..............................Magnetisch relais (Y1S) (A1P)
K9R ..............................Magnetisch relais (Y2S) (A1P)
K10R ............................Magnetisch relais (Y3S) (A1P)
K11R ............................Magnetisch relais (Y2R) (A1P)
K12R ............................Magnetisch relais (Y3R) (A1P)
L1R ...............................Reactor
M1C,2C,3C ...................Motor (compressor)
MF11,12F .....................Motor (ventilator)
MF21,22F .....................Motor (ventilator)
MF3,4F .........................Motor (ventilator)
Q11M,12M....................Thermische beveiliging (M11F, M12F)
Q21M,22M....................Thermische beveiliging (M21F, M22F)
Q3M,4M........................Thermische beveiliging (M3F, M4F)
R1.................................Weerstand
R66-69..........................Weerstand
R93,94..........................Weerstand
R1T...............................Thermistor (AIR) (A1P)
R1T...............................Thermistor (FIN) (A2P)
R21,22T........................Thermistor (spoel)
R23T.............................Thermistor (spoel)
R31-33T .......................Thermistor (retour)
R41-43T .......................Thermistor (vertakking)
R6T...............................Thermistor (spoel)
R8T...............................Thermistor (vloeistof)
SENPH .........................Druksensor (hoog)
SENPL..........................Druksensor (laag)
Q1PH-3PH ...................Pressure switch (hoog)
TB1,2,3.........................Aansluitprintplaat (relais)
T1R,2R .........................Transformator (220-240V/22V)
X1M ..............................Aansluitstrip (voeding)
X2M ..............................Aansluitstrip (besturing)
X3M ..............................Aansluitstrip (relais)
Y1E-3E .........................Elektronische expansieklep
9
Y1R-Y3R ......................Vierwegklep
Y1S...............................Magneetklep (extra condensor)
Y2S...............................Magneetklep (hete damp)
Y3S...............................Magneetklep (inspuiting M1C)
Y6S...............................Magneetklep (inspuiting M2C)
Y4S...............................Magneetklep (ontvanger)
Y7S...............................Magneetklep (inspuiting M3C)
Y5S...............................Magneetklep (vloeistof druk)
Z1F-6F..........................Ruisfilter (overspanningsbeveiliging)
...........................Diodemodule
D M
P C
...........................Voedingschakeling
P M
...........................Voeding
PRC
...........................Faseomkeerdetectieschakeling
S D
...........................Ingang veiligheidsvoorzieningen
Bekabeling buiten de unit
L1,L2,L3
Fasedraad
N
Nul
Aansluiting
Draadklem
Massa-aansluiting (parafusos)
Kleuren
BLK : Zwart
BLU : Blauw
BRN: Bruin
Opmerking
Gebruik alleen koperen geleiders
Zie het hoofdstuk "Voorbeelden" wanneer de adapter voor
sequentieel opstarten wordt toegepast.
Meer informatie over de stuurbekabeling tussen twee buitenunits
F1-F2, een buitenunit en een binnenunit F1 F2, vindt u in het
hoofdstuk "Voorbeelden".
Meer informatie over de stuurbekabeling naar de centrale
afstandsbediening vindt u in de installatiehandleiding van de cen-
trale afstandsbediening.
Gebruik een geïsoleerd snoer voor het voedingssnoer.

7-2 Voedingschakeling en bekabelinguitvoering

Het apparaat moet worden aangesloten op een elektrische installatie
(zie onderstaande tabel). Deze installatie moet volgens de ter plaatse
geldende voorschriften worden beveiligd met tenminste een hoofd-
schakelaar, een trage zekering of elke fase en een aardlekschakelaar.
Fase en fre-
Spanning
quentie
RSEYP16
3N~50Hz
380-415V
RSEYP18
3N~50Hz
380-415V
RSEYP20
3N~50Hz
380-415V
RSEYP24
3N~50Hz
380-415V
RSEYP26
3N~50Hz
380-415V
RSEYP28
3N~50Hz
380-415V
RSEYP30
3N~50Hz
380-415V
Wanneer een aardlekschakelaar wordt toegepast, moet dit een snelle
200 mA-aardlekschakelaar zijn.
Opmerking
Gebruik bekabeling met een diameter die voldoet aan de ter
plaatse geldende en landelijke voorschriften.

7-3 Algemeen

Sluit de voedingskabel aan op de voedingsaansluitingen van het
apparaat en zet de kabel vast op de manier zoals is weergegeven
in afbeelding 17 van het hoofdstuk "Aansluiten op de installatie".
Dit apparaat is voorzien van een gelijkstroom - wisselstroo-
momzetter. Door een faseversnellingscondensator te installeren
wordt het effect van de verbetering van de vermogensfactor teni-
etgedaan. Daarnaast bestaat de mogelijkheid dat de condensator
oververhit raakt als gevolg van hoogfrequente trillingen, waardoor
ongevallen kunnen ontstaan. Installeer dus nooit een faseversnel-
lingscondensator.
GRY : Grijs
RED : Rood
ORG : Oranje
WHT : Wit
PNK : Rose
YLW : Geel
Aanbevolen zek-
Diameter bestur-
eringen
ingsbekabeling
45A
0,75-1,25mm
50A
0,75-1,25mm
60A
0,75-1,25mm
60A
0,75-1,25mm
70A
0,75-1,25mm
70A
0,75-1,25mm
70A
0,75-1,25mm
2
2
2
2
2
2
2

Advertenties

Inhoudsopgave
loading