Speci caties
Typeaanduiding
1)
Hoge/normale overbelasting
Typisch asvermogen [kW (pk)]
Beschermingsklasse behuizing IP 20
Beschermingsklasse behuizing IP 21, IP 55, IP
66
Uitgangsstroom
Continu (380-440 V) [A]
Intermitterend (60 s overbelasting)
(380-440 V) [A]
Continu (441-500 V) [A]
Intermitterend (60 s overbelasting)
(441-500 V) [A]
Continu kVA (400 V) [kVA]
Continu kVA (460 V) [kVA]
Maximale ingangsstroom
Continu (380-440 V) [A]
Intermitterend (60 s overbelasting)
(380-440 V) [A]
Continu (441-500 V) [A]
Intermitterend (60 s overbelasting)
(441-500 V) [A]
Aanvullende speci caties
IP 21, IP 55, IP 66, maximale
2,5)
kabeldoorsnede
voor net, rem en
loadsharing [mm²] ([AWG])
IP 21, IP 55, IP 66, maximale
2,5)
kabeldoorsnede
voor motor [mm²] ([AWG])
IP 20, maximale kabeldoorsnede
rem, motor en loadsharing [mm²] ([AWG])
2,5)
Maximale kabeldoorsnede
voor netscha-
kelaar [mm²] ([AWG])
Geschat vermogensverlies bij nominale
3)
maximumbelasting [W]
4)
Rendement
Tabel 8.5 Netvoeding 380-500 V (FC 302), 380-480 V (FC 301), P11K-P22K
MG33AT10
Bedieningshandleiding
P11K
HO
NO
11 (15)
15 (20)
B3
B1
24
38,4
35,2
21
33,6
29,7
16,6
22,2
–
21,5
22
35,2
31,9
19
30,4
27,5
16, 10, 16 (6, 8, 6)
10, 10,- (8, 8,-)
2,5)
voor net,
10, 10,- (8, 8,-)
291
392
0,98
Danfoss A/S © 05/2018 Alle rechten voorbehouden.
P15K
HO
NO
15 (20)
18,5 (25)
18,5 (25)
B3
B1
32
32
37,5
51,2
41,3
27
27
34
43,2
37,4
22,2
26
–
27,1
29
29
34
46,4
37,4
25
25
31
40
34,1
16, 10, 16 (6, 8, 6)
10, 10,- (8, 8,-)
10, 10,- (8, 8,-)
16, 10, 10 (6, 8, 8)
379
465
0,98
P18K
P22K
HO
NO
HO
22 (30)
22 (30)
30 (40)
B4
B4
B2
B2
37,5
44
44
60
48,4
70,4
34
40
40
54,4
44
64
26
30,5
30,5
–
31,9
–
34
40
40
54,4
44
64
31
36
36
49,6
39,6
57,6
35,-,-(2,-,-)
35,-,-(2,-,-)
35, 25, 25 (2, 4, 4)
35, 25, 25 (2, 4, 4)
35,-,-(2,-,-)
35,-,-(2,-,-)
444
525
547
0,98
0,98
NO
61
67,1
52
57,2
42,3
41,4
55
60,5
47
8
8
51,7
739
37