NOTE
• The device plug must not be placed directly behind the ventilation
grill in order to prevent the air circulation from being impaired and to
protect the device plug from splashes of water.
• The device plug of the AC connection cable must not be cut off.
• The connection cables must be laid so that they do not come in con-
tact with hot parts of the unit/burner or with sharp edges.
• Changes to the internal electrical installation or the connection of
other electrical components (e.g. extra third party fans) to the inter-
nal wiring of the refrigerator will void any claims from the guarantee
and product liability.
• The refrigerator has a CI bus interface and can be controlled through
a compatible central vehicle display.
Circuit diagram of the refrigerator (fig. i, page 11)
No. in
fig. i, page 11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
EN
Description
Fan 2 (if options module is not available)
Fan 1 (if options module is not available)
S+ (optional)
Heating element DC
DC relay with 20 A fuse for heating cartridge
NTC 1: Refrigeration room
NTC 2: Outside temperature (optional)
Gas valve
AC power supply
Heating element AC
Gas burner
Connection block
Lightning
Display
Heating frame
Fan 2 (if options module is available)
Fan 1 (if options module is available)
Connecting the refrigerator