SIMUDRIVE SD100Hz
Anti-fallback indicator light
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the anti-fallback wiring.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door
to be controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Wired control indicator light
Normal operation
Control activated
→ Mechanically check that the control point is not blocked. If the control point is not blocked,
disconnect the control point. If the indicator light goes out, check the wiring.
Cells, safety edge, anti-fallback and wired control indicator light
Short circuit on connected peripherals wired input
→ Check that the peripherals connected and their wiring function correctly.
→ If the indicator lights are still flashing, switch the power off, disconnect the peripherals from
terminals 10 to 21, wait 30 s then switch the power back on: if the 4 indicator lights stop
flashing, check the wiring of the cells, of all the peripherals connected to this power supply and
of the peripherals connected to the wired inputs.
→ If the indicator lights are still flashing, switch the power off, remove the green terminal block
(12-13-14), wait 30 s and then switch the power back on: if the 4 indicator lights stop flashing,
check the wiring of the safety edge.
→ If the indicator lights are still flashing, switch the power off, remove the red terminal block
(10-11), wait 30 s and then switch the power back on: if the 4 indicator lights stop flashing,
check the wiring of the anti-fallback mechanism and then refit the terminal block. Start a
movement to make sure there is no short-circuit.
→ If the 4 indicator lights continue to flash, contact Simu technical assistance.
All the indicator lights
Locking/unlocking the programming buttons
→ If all the indicator lights flash when a programming button is pressed, the keypad is locked.
Unlock it, see Locking the programming buttons [} p.39]
PROG indicator light
No radio reception when a button is pressed on the remote control
→ Check if the remote control button has been programmed.
→ Check that the remote control is equipped with Simu-Hz radio technology.
→ Check the remote control batteries.
Radio control received but no action by the actuator
→ Check the other indicator lights to see if there is another fault.
→ The control is not operational from this position.
→ The button is memorised for a function other than opening/closing the garage door (for
example controlling the auxiliary output).

10.3 Safety devices failure

In the event of a failure of the safety mechanism (photoelectric cells or reflex cell, safety edge, anti-fallback),
after 3 minutes a key contact connected between terminals 20 and 21 allows the door to be controlled in
dead-man mode.