Photoelectric cell safety input
Comments
P3 = 2: the auto-test is run on the device for each operating cycle via power supply
switching.
WARNING! Installation of photoelectric cells WITH AUTO-TEST P3=2 is
mandatory if:
P3 = 4: the safety input is not taken into account
WARNING! If P3=4, the operation of motorisation in automatic mode is
prohibited and control of the motorisation by sight is mandatory.
7

PROGRAMMING THE REMOTE CONTROLS

7.1

Memorising 2 or 4-button remote controls

NOTICE
If this procedure is carried out using a button which has already been memorised, the button will be
cleared.
1] Press the "PROG" button for 2 s.
ð The "PROG" indicator light is permanently lit.
NOTICE
Pressing "PROG" again allows the next function to be memorised (230 V aux output control)
2] Press the button selected to control the function (complete opening, 230 V aux output control).
ð The "PROG" indicator light flashes for 5 s.
Complete opening control
Memorising the remote controls [} p.33]
230 V aux output control
> Illustration 21
7.2

Memorising 3-button remote controls

> Illustration 22
NOTICE
If this procedure is carried out using a remote control which has already been memorised, the remote
control will be cleared.
1] Press the "PROG" button for 2 s.
ð The "PROG" indicator light is permanently lit.
NOTICE
Pressing "PROG" again allows the next function to be memorised (230 V aux output control)
2] Press "PROG" at the back of the remote control.
ð The "PROG" indicator light flashes for 5 s.
Function of the 3-button remote control buttons
Function
Complete opening
Aux. 230 V
38
• remote control of the mechanism is used when the door is not visible,
• automatic closing is activated (P0 = 2 or 3 ).
Up button
Complete opening
Aux. output ON
My button
Stop
SIMUDRIVE SD100Hz
Down button
Complete closing
Aux. output OFF