SIMUDRIVE SD100Hz
CAUTION
The order of these operations must be complied with.
1] Remove the bridge between terminals 19 and 20.
2] Connect the cells.
• A - without auto-test
• B - with auto-test: allows an automatic operating test to be conducted on the photoelectric cells
every time the doors moves.
3] Program parameter P3.
• Active without auto-test: "P3" = 1
• Active with auto-test by means of power switching: "P3" = 2
Meaning of the different parameters [} p.37]
5.2.2
Reflex photocell
> Illustration 15
WARNING
It is compulsory to install photoelectric cells WITH AUTO-TEST P3 = 3 if:
• remote control of the mechanism is used when the door is not visible,
• automatic closing is activated ("P0" = 2 or 3).
CAUTION
The order of these operations must be complied with.
1] Remove the bridge between terminals 19 and 20.
2] Connect the cell.
3] Program parameter "P3" = 3.
Meaning of the different parameters [} p.37]
5.2.3
230 V orange light
> Illustration 16
WARNING
The cable clamp must be used.
Program parameter "P1" = 1.
Meaning of the different parameters [} p.37]
5.2.4
230 V area lighting
> Illustration 17
CAUTION
The earth wire must always be longer than the live and neutral wires in case of detachment.
The cable clamp must be used.
The lighting output must be protected by a 5 A time-delay fuse (not supplied).
1] For class I lighting, connect the earth wire to the earth terminal.
2] Program parameter "P1" = 2.
Meaning of the different parameters [} p.37]
Lighting output power:
• either 5 fluocompact or LED lights
• or 2 power supplies for low-voltage LEDs
• or 1 halogen light, max. 500 W
5.2.5
Key contact
> Illustration 18
EN