EN
10 DIAGNOSTIC AND TROUBLESHOOTING
10.1 Indicator light status
Off
Permanently lit
10.2 Diagnostic
POWER indicator
Electronic in motor setting mode
→ If necessary, check the motor's direction of rotation and set the motor's end stops.
Product set
Motor thermal cut-out
→ Switch the power supply off, wait about 5 min. then switch the power supply back on.
Photoelectric cells indicator light
Normal operation
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check cell alignment and the associated wiring.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door
to be controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Safety edge indicator light
Normal operation
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the safety edge wiring.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door
to be controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Anti-fallback indicator light
Normal operation
40
SIMUDRIVE SD100Hz
Slow flashing
Rapid flashing
Very rapid flashing