Chapter 4 Maintenance and remedy of generator set
Oil fuel is not enough
The switch is not at "ON" position
The pump of high pressure and oil
nozzle can not inject oil or the oil
amount is not enough
The
The control lever of speed is not at
diesel
"RUN" position
engine
can no
Check the level of lubricant
start
The speed and force to pull the
recoil starter is not enough
The oil nozzle has dirty
The battery has no electricity
Main switch(AC SW) is not closed
The
Capacitor damage
generator
can not
The contact of socket is not closed
generate
The rated speed of generator can
not be reached
If electricity is still not generated, take the generator to a dealer.
Cause
Add oil fuel
Turn it to "ON" position
Remove the oil nozzle out and repair it
at test table
Put the control level to "RUN" position
The specified oil level should be
between upper level "H" and lower
level "L"
Start the diesel engine according to the
requirements of operating procedure of
start
Clean the nozzle
Charge it or replace it with a new one
Put the main switch to the "ON" position
Change capacitor
Adjust the feet of socket
Adjust it according to the requirement
33
Remedy