Download Print deze pagina

Auga VarioFlow E Gebruiksaanwijzing pagina 33

Vijver

Advertenties

Beschikbare talen

Beschikbare talen

Clean all parts with clean water and a soft sponge.
Replace broken/damaged parts.
Assembly: (figure 7)
Put the rotor (5) back into the motor (9).
WARNING: the magnet is very powerful and it will jump
back into the motor with some force. You could be
injured if you do not pay attention!
Replace the o-ring (4) and check to ensure this is positioned properly.
Check to ensure that the rotor (5) can turn around.
Replace the pump housing (3) on the motor (9) and then secure evenly
using the pumping house screws (8).
Place the motor (9) with the pump housing (3) back into the shaft (10).
Replace the non-return ring (11) and fix them in place using the screws
(12).
Place the suction basket (2) back on the pump housing (3) if the suction
basket (2) is being used.
Once everything is assembled, the pump can be switched on again.
Parts list: (figure 7)
Provide the drawing number, the description and the pump type when ordering.
No. Description
1
Logo plate
2
Suction basket
3
Pump housing
4
O-ring
5
Rotor
6
Bearing
7
Bearing holder
8
Pump housing screws
9
Motor
10
Foot
Parts that can be ordered from your dealer.
Winter period
Protect the pump against freezing during winter; if necessary, pump the
water out of the system or remove the pump from the water.
Clean the pump as described earlier, before putting it in storage.
Place the pump in a water container at a frost-free location to prevent
the rubber seals from drying out.
Removal and storage of waste
All household electrical appliances must be disposed of in accordance with EU
directives. The product may not be disposed of with the normal household waste,
but should be collected separately. You are personally responsible for bringing the
device to a designated landfill site. It must be dismantled and processed in an
environmentally-friendly manner.
More information on local landfill sites can be obtained from the municipality in
which you live.
English
www.auga.nl
No. Description
11
Non-return ring
12
Screws
13
VarioFlowControl panel
14
Hose fitting seal
15
Hose fitting
16
Nut
17
Adhesive connection seal
18
Adhesive connection
19
Rubber foot
33

Advertenties

loading

Deze handleiding is ook geschikt voor:

Varioflow e-10Varioflow e-20Varioflow e-30