Repair is not possible since the cable is moulded into the motor and is
•
therefore not replaceable.
Do not move or suspend the pump by the power cord.
•
Keep the plug dry. To prevent water from running from the cord to the
•
plug, suspend the cord in a U-shape. (see figure 4.)
Hang the controller in a well-ventilated place that is protected from
•
direct sunlight and moisture / rain. The back wall must not be made of
easily inflammable material. (Pic 9)
When working on the pump, always unplug from the electrical outlet to
•
cut off the power supply.
The pump may only be used if it has an adequate supply of water.
•
The pump may only be used for pumping fresh water, without any
•
chemical additives or other aggressive components, with a maximum
temperature of 35°C.
Commissioning the pump when installing in water (figures 1, 6 and 8).
Important: Do not run the pump dry as this may damage the pump.
Place the pump in the water to fill it up.
•
To avoid unnecessary contamination, place the pump on solid stone tiles
•
to prevent it from standing in and ingesting sludge.
Make sure that the water is at least 10cm deep to prevent the pump
•
from sucking air.
Maximum immersion depth of the pump is 2 m under water.
•
Place the pump housing in the appropriate position and assemble the
•
accessories on the cable connection to the pump.
Plug the male power plug (4-pin) of the power cord into the control
•
panel's 4-pin (4-pin) female plug. Make sure that the O-ring of the male
plug (4-pin) is in place. Screw the nut tightly.
Place the control panel in a ventilated place, a non-combustible substrate
•
and protected from direct sunlight and moisture.
Start the pump by inserting the plug into the socket and using the
•
VarioFlow-E control panel (see Operating pump) to turn it on
Care should be taken to protect the pump from frost and freezing.
•
Commissioning the pump in dry installation conditions:
(figures 2, 3, 6 and 8)
The pump can also be installed out of the water.
Remove the pump suction basket.
•
Place the pump underwater next to the pond so that water can flow into
•
the pump (the pump will not suck in water of its own accord).
Put the pump housing in the right position and connect a suction
•
hose/pipe (Z) and pressure hose/pipe (D) to the pump and ensure they
are air and watertight.
In order to use the pump, the suction hose/pipe (Z) must have been
•
filled with water.
Plug the male power plug (4-pin) of the power cord into the control
•
panel's 4-pin (4-pin) female plug. Make sure that the O-ring of the male
plug (4-pin) is in place. Screw the nut tightly.
Place the control panel in a ventilated place, a non-combustible substrate
•
and protected from direct sunlight and moisture.
Start the pump by inserting the plug into the socket and using the
•
VarioFlow-E control panel (see Operating pump) to turn it on
English
www.auga.nl
31