INSTALLATION
Gas connection
Caution!
The cooker should be connected to a
gas supply of the particular type of gas
that the appliance is manufactured to
function with. Information about the
type of gas that the cooker has been
adapted to by the factory is shown on
the data plate. The cooker should be
connected exclusively by an appropri-
ately authorised fitter and only he or
she has the right to adapt the cooker
to a different type of gas.
Fitting guidelines
A fitter should:
have a gas fitter's authorisation,
be acquainted with the information in-
cluded on the data plate of the cooker
about the type of gas to which the cooker
is adapted; the information should be
compared with gas supply conditions at
the place of installation,
check:
- airing efficiency, that is efficiency of air
exchange in the rooms,
- tightness of gas fitting connections,
- effectiveness of all functional elements of
the cooker,
- if the electricity supply is adapted to func-
tion with a safety ground lead (zero).
provide the user with a connection cer-
tificate and give him or her instructions
in cooker use.
Caution!
The cooker may only be connected
to a liquid gas cylinder or the existing
gas supply by an authorised fitter,
observing all safety rules.
Connection with a flexible steel hose.
If the cooker is connected according to the
class 2 specifications, sub-class I, only flex-
ible metal hose can be used which meet the
valid national regulations. Gas feeding con-
nector must be G ½" threaded coupling.
Use only pipes and fittings that meet the
requirements of the valid standards. Maxi-
mum admissible length of the flexible hose
is 2000 mm.
Make sure the connection is not touching
any mobile elements which could damage
the hose.
Connection with a stable pipework.
The cooker comes with a G ½" threaded
coupling.
The connection to gas supply must be done in
a manner that excludes stresses in any point
of the pipework or parts of the appliance.
Make sure you do not exceed the torque
when making the connection (maximum
torque is 20 Nm). Otherwise, the connection
may be faulty or leaks may occur.
The gas hose should not touch metal ele-
ments of the cooker back shield.
Important!
Each time you replace a reducer
carry out technical inspection of the
cooker that covers gas valves and
proper operation of the flame failure
cut-off device.
Caution!
On completion of the cooker installa-
tion, the tightness of all connections
should be checked, e.g. applying
water with soap.
Do not use fire to check tightness.
14