Download Print deze pagina

S-Registers Quick Reference; Modem S-Registers - Bausch Datacom Proxima USB V.90 56K Gebruikershandleiding

Advertenties

Beschikbare talen

Beschikbare talen

PROXIMA USB
79
CONNECT 50000
79
CONNECT 50000 EC*
80
CONNECT 52000
80
CONNECT 52000 EC*
81
CONNECT 54000
81
CONNECT 54000 EC*
82
CONNECT 56000
82
CONNECT 56000 EC*
86
CONNECT 16800
86
CONNECT 16800 EC *
87
CONNECT 115200
87
CONNECT 115200 EC *
*
EC is replaced by one of the following symbols.
V.42bis
V.42 error control and V.42bis data compression
V.42
V.42 error control only
MNP5
MNP 4 error control and MNP 5 data compression
MNP4
MNP 4 error control only
NoEC
No error control and data control protocols
Appendix B: S-Registers Quick Reference

Modem S-Registers

S-Registers, ATSn=x"
Register
Dec.
S0=
0 - 255
S1=
0 - 255
S2=
0 - 255
S3=
0 - 127
S4=
0 - 127
S5=
0 - 32,
127
S6=
2 - 65
4 - 65
S7=
1 - 255
35 - 59
S8=
0 - 65
S10=
1 - 255
S11=
50 -
150
S12=
0 - 255
S28=
0 - 255
Function & Description
Set the number of the rings required before the modem aut omatically answers
a call. Set 0=0" to disable auto-answer mode
Count the incoming rings and store the value to this register. The value of this
register is incremented with each ring. If no rings occur over an 8 sec. interval,
this register is cleared. User can read but should not change this value
S2 holds the decimal value of the ASCII character used as the escape character.
The default value (043) corresponds to
an ASCII character "+". A value of 128
to 255 disables the escape process, i.e.,
no escape character will be recognized
Hold the decimal value of the Carriage Return <CR> character used as the
command line and result code terminator. Pertain to asynchronous operation only
Hold the decimal value of the character recognized as a line feed. The line feed
control character is output after the carriage return control character if verbose
result code are used.
Hold the decimal value of the character recognized as a backspace. The
modem will not recognize the backspace character if this register is set to a
value greater than 32
Set the length of time, in seconds, that the modem must wait (minimum 2
seconds even if the value is less than 2) after going o f f -hook before dialing the
first digit of the telephone number
For international version
For Japanese version
Set the time, in seconds, that the modem must wait before hanging up because
carrier is not detected
For international version
For Japanese version
Set the time, in seconds, that the modem must pause when the "," dial modifier
is encountered in the dial string
Set the length of time, in tenths of a second, that the modem waits before
hanging up after a loss of carrier
DTMF duration and inter digit delay. Set the duration and spacing, in mini-
seconds, in DTMF touch tine dialing
Define the maximum period, in 2-hundredths of a second, allowed between
consecutive asynchronous escape character "+" (plus) for the escape
sequence to be considered valid
V.34 modulation en-/disabler
0: disabled
1- 255: enabled
64
BAUSCH DATACOM
3
3
3
3
3
3
3
3
3
3
3
3
Default
000
000
043
013
010
008
002
004
050
050
002
020
095
050
001

Advertenties

Hoofdstukken