PROXIMA USB
W0*
W1
W2
Xn
X0
X1
X2
X3
X4 *
X5
X6
X7
Zn
Z0
* Manufacturer default
Extended "AT&" (Ampersand) Command Set
Command
Options
&Cn
&C0
&C1 *
&Dn
&D0
&D1
&D2 *
&D3
&F
&Gn
&G0 *
&G1
&G2
&Kn
&K0
&K3 *
&K4
&Pn
&P0
&P1
&Qn
&Q0
&Q5 *
&Q8
&Q9
&Sn
&S0 *
&S1
&Tn
CONNECT result code reports DTE speed. Disable protocol result codes.
(see also the "Result Code Options Table")
CONNECT result code reports DTE speed. Enable protocol result codes.
CONNECT result code reports DCE speed. Enable protocol result codes.
Select result codes/call progress options
Display CONNECT or "1" for all speeds.
Ignore dial tone and busy tone detection.
Display connect message and the modem's data rate, and an indication of the
modem's error correction and data compression.
Ignore dial tone and busy tone detection.
Display connect message and the modem's data rate, and an indication of the
modem's error correction and data compression.
Check dial tone before proceeding dialing,
ignore busy tone detection.
Display connect message and the modem's data rate, and an indication of the
modem's error correction and data compression.
Ignore dial tone before proceeding dialing,
check busy tone after making dialing.
Display connect message and the modem's data rate, and an indication of the
modem's error correction and data compression.
Check dial tone and busy tone.
Same as X4.
Same as X4.
Display CONNECT or "1" for all speeds.
Check dial tone and busy tone.
Recall stored profile
Reset and recall user profile 0. Either Z0 or
Z1 restores the same single profile.
Function & Description
Data carrier detect option
State of carrier from remote modem is ignored. DCD circuit is always on
DCD turns on when the remote modem's carrier signal is detected, and off when the
carrier signal is not detected.
Data Terminal Ready (DTR) option.
DTR ignored
Go to command mode on on-to-off DTR transition
Hang up and go to command mode on on-to-off DTR transition. Auto-answer is
disabled if DTR is low
Hang up and reset from user profile 0 on the on-to-off DTR transition
Recall factory default setting as active configuration
V.22bis guard tone option
No guard tone
550 Hz guard tone
1800 Hz guard tone
Set local flow control
Disable flow control
Enable bi-directional hardware flow control (CTS/RTS)
Enable bi-directional software flow control (XON/XOF F)
Pulse dialing make/break ratio selection
Make=39%, Break=61%, international version (Default)
Make=33%, Break=67% for use in 20 pps, Japanese version
Make=33%, Break=67%, international version
Make=33%, Break=67% for use in 10 pps, Japanese version (Default)
Async communications mode options
Async mode, buffered (same as "AT\N0")
Error control mode, buffered (same as "AT\N3")
MNP error control mode. If an MNP error control protocol is not established, the
modem will fallback according to the current setting in S36 register.
V.42 or MNP error control mode. If neither error control protocol is established, the
modem will fallback according to the current setting in S36 register.
Data Set Ready (DSR) option
DSR always on
DSR on during handshake and on-line, off in test mode or idle mode
Self -test commands
60
BAUSCH DATACOM