3.10 Frame test
Please make sure that the workstation frame can move freely and correctly at all
times.
In case you need to disconnect cables from the electrical components always be
sure to disconnect power first.
In case the height adjustment is not operating normally, stop using the workstation
frame immediately and disconnect the power. Get in contact with customer service
for further advise
12
Reset Mode
The first time you put in the plug of the power supply into the socket the height adjustment can only
be operated in the reset-mode. As long as the reset-mode is enabled, the system can only move
downward. In order to use the system normally, please follow the next steps:
Press and hold the down-button, the system slowly moves downward.
•
Please move the system to the lowest position. This position will be used as reference-point (zero-
•
point).
Keep the button pressed for a moment when the system has reached the lowest position. This
•
will end the reset-mode.
The system can be operated normally now. Press and hold the up- or down-button to move the
•
system to the desired height. The system stops when you release the buttons.
UP
DOWN
English
15