RPD50
Connecting to a battery
The refrigerator can be operated with a 12 Vg to 24 Vg voltage supply.
A
NOTICE!
To avoid voltage loss and therefore a drop in performance, the cable
should be kept as short as possible and should not be interrupted if this
is possible.
For this reason avoid additional switches, plugs or power strips.
➤ Determine the required cross section of the cable in relation to the cable length
according to fig. 7, page 5.
Key for fig. 7, page 5
Co-ordinate axis
l
∅
A
NOTICE!
Make sure that the polarity is correct.
➤ Before starting up the device for the first time, check whether the
operating voltage and the battery voltage correspond (see type plate).
➤ Connect the refrigerator
– As directly as possible to the pole of the battery or
– To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at 24 V).
A
NOTICE!
Disconnect the cooling device and other power consuming devices
from the battery before connecting the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
EN
Setting up and connecting the refrigerator
Meaning
Cable length
Cable cross section
Unit
m
mm²
15