13 Bijlage
Read access protection active mode
Command
Response
aXRAPAM!
a<value> <CR><LF>
Example:
Command
Response
aXRAPAM!
0+1<CR><LF>
Write access protection parameterization unlock
Command
Response
aXWAPPUL <va-
a<value1><CR><LF>
lue1>!
Example:
Command
Response
aXWAPPUL
0+000<CR><LF>
+123456!
Write access protection parameterization lock
Command
Response
aXWAPPL!
a<value><CR><LF>
Example:
Command
Response
aXWAPPL!
0+000<CR><LF>
Write access protection unlock with emergency code
Command
Response
aXWAPEC <va-
a<value1><CR><LF>
lue1>!
Example:
54
Description
a: sensor address
<value>: mode, +0 = none, +1 = device code
(active)
<CR><LF>
Description
Description
a: sensor address
<value1>: 6 numbers (device unlock code)
<CR><LF>
Description
Description
a: sensor address
<value>: VVO-Status +eee
<CR><LF>
Description
Description
a: sensor address
<value1>: 10 numbers (device emergency unlock code)
<CR><LF>
<value1>: VVO-Status
VEGAPULS C 22 • SDI-12