Download Inhoudsopgave Inhoud Print deze pagina

Extended Commands - Vega VEGAPULS C 22 Handleiding

Verberg thumbnails Zie ook voor VEGAPULS C 22:
Inhoudsopgave

Advertenties

13 Bijlage
– +ssss.s (mm)
– +sss.ss (in)
Distance
– +dd.ddd (m)
– +dd.ddd (ft)
– +dddd.d (mm)
– +ddd.dd (in)
Electronics temperature
– ttt.t (°C, °F, K)
Measurement reliability
– rrr.r (dB)
Device status
– eee (Errror code)
Example
Address = 0, Stage = 29,272m, Distance = 0,728m, Temperature = 25,4°C, reliability = 14,0 dB,
Device Status = Good
Response : 0+29.272+0.728+25.4+14.0+0<CR><LF>
Address = 4, Stage = 14,887m, Distance = 0,113m, Temperature = 22,7°C, reliability = 14,0dB,
Device Status = M507 (Error in the device setting)
Response : 4+14.887+0.113+22.7+14.0+507<CR><LF>

13.4 Extended Commands

Command
aXRPOM!
aXWPOM<value1>!
aXRDU!
aXWDU<value1>!
aXRTU!
aXWTU<value1>!
aXRSR!
aXWSR<value1>!
aXRAPUR!
aXRPS!
aXRAPAM!
aXWAPPUL<value1>!
aXWAPPL<value1>!
aXWAPEC<value1>!
50
Response
a<value1><value2><CR><LF>
a<value1><value2><CR><LF>
a<value1><CR><LF>
a<value1><value2><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><value2><CR><LF>
a<value1><value2><CR><LF>
a<value1><value2><CR><LF>
a<value1><value2><value3><va-
lue4><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
Description
Read Power Operation Mode
Write Power Operation Mode
Read distance unit
Write distance unit
Read temperature unit
Write temperature unit
Read stage reference
Write stage reference
Read access protection unlock result
Read parametrization state
Read access protection active mode
Write access protection parametrization lock
Write access protection parametrization unlock
Write access protection unlock with emergency co-
de
VEGAPULS C 22 • SDI-12