Download Inhoudsopgave Inhoud Print deze pagina

Electrical Wiring; Control-Box; Photoresistance; Pin Plug - Riello Gulliver RG0.R Installatie-, Gebruiks- En Onderhoudsvoorschriften

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

3.4 ELECTRICAL WIRING

WARNING
DO NOT EXCHANGE NEUTRAL WITH PHASE
~
50Hz 230V
PE L
N
Safety
thermostat

7 pin plug

7 pole socket
D1888
Ignition
electrodes
CONTROL BOX
To remove the control-box from the burner, loosen screw (A, fig. 9)
after removing all components, the 7 pin plug and earth wire.
In case of disassembly of the control box, retighten the screw
(A) with a torque wrench setting of 1 – 1.2 Nm.
2596
Main switch
T6A
Limit
thermostat
Brown
Blue
Black
White
Blue
Heater with start
thermostat
Burner-earth
NOTES:
– Wires of min. 1 mm
otherwise by local standards and legislation).
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
Hour counter
(230V - 0.1A max.)
Remote lock-out signal
(230V - 0.5A max.)

Photoresistance

Oil valve
Air damper
coil
Motor
5
GB
2
section. (Unless requested
TESTING
Check the shut-down of the
burner by opening the thermo-
stats and the lock-out by dark-
ening the photoresistance.
Capacitor
Fig. 9
S7186
A