13. BUILT-IN CONTROL – CONNECTION DIAGRAM SLIM E;
PIC. 13.1 POWER SUPPLY 1N ∼ 230V/50 Hz
❶ Power supply:
1N ∼ 230V/50Hz:
SLIM E-100 (min.3x1,5 mm
SLIM E-150 (min.3x1,5 mm
SLIM E-200 (min.3x2,5 mm
3N ∼ 400V/50Hz:
SLIM E-100 (min.5x2,5 mm
SLIM E-150 (min.5x2,5 mm
SLIM E-200 (min.5x4,0 mm
-
-
ADVICE
-
❸ Motion sensor; to omit/bypass the motion sensor; disconnect and insulate / secure wires from connectors D; D, a cable jumper
(min. 1x1,0 mm
) or a door sensor (min. 2x1,0 mm
2
❹ Heating switch ( I – heating elements ON , O – heating elements OFF);
❺ Fan step switch ( I – 1st fan step, O – device OFF, I I – 3rd fan step).
1) To connect the 2nd fan step, connect the cable from the 6th connector to the 7th connector. In this case,
the I position on the switch will mean SWITCHING ON the 2nd fan step.
2) Each time the curtain is turned on by a motion sensor, it operates for a set time (10 s by default), unless
motion is detected in the area covered by the sensor.
ADVICE
3) The device starts automatically when motion is detected in the sensor area and works according to settings
selected on the switches.
In the event of a hazard arising from the unintentional reset of the thermal switch, this equipment should not
be powered by an external connecting device, such as a time switch, or a disconnector connected to the
WARNING
circuit, which is regularly switched OFF and ON during use.
; Protection B10)
2
; Protection B16)
2
2
; Protection B20)
; Protection B10)
2
; Protection B16)
2
2
; Protection B20)
The maximum outer diameter of the cable sleeve is 14.0 mm;
The minimum outer diameter of cable sleeve is 4.0 mm;
Maximum wire diameter 4,0 mm
) should be connected in this place;
2
PIC. 13.2 POWER SUPPLY 3N ∼ 400V/50 Hz
2
.
13