9.4.2.1 Disassembly of glass pane in door
To remove the glass pane in the door, please follow the instructions below (see Annex 2, fig. 12):
Ø
Open the door.
Ø
Lift out the door by sliding it upwards.
Ø
Place the door on a flat surface.
Ø
Remove the door seal.
Ø
Unscrew the nuts under the door seal from the glass strip.
Ø
Remove the glass strips.
Ø
Lift the glass pane out. The pane seal is also taken out.
When replacing the glass pane always replace the glass pane seal in the door (= seal between the glass pane and
!Tip
the door) AND the door seal (= seal between the door and the fire).
9.4.2.2 Disassembly of side pane
The side pane must be replaced in case of cracks or fractures in the glass pane.
Follow the instructions below:
Ø
Unscrew the Allen screws (see Annex 2, fig. 11). This action should also be executed when cleaning the side pane.
Ø
Now follow the steps described in paragraph 9.4.2.1 'Disassembly of glass pane in door'.
9.4.2.3 Assembly of glass pane in door
Assemble the glass pane in the door according to the steps described in paragraph 9.5.1.1 'Disassembly of glass
pane in door', only in reverse order.
•
!Caution
•
•
•
Make sure that the sleeve is placed on the underside of the glass pane.
!Caution
9.4.2.4 Assembly of side pane
For assembly of the side pane, please observe the instructions provided in paragraph 9.5.1.2 'Disassembly of side
panes', only in reverse order.
Properly press down the side door during assembly, before the Allen screws are tightened again! The side door
!Caution
must fit onto the appliance properly, in order to prevent leakage and attraction of false air.
9.5 Appliance-specific information: Instyle Triple 660 Low
9.5.1 Interior lining
9.5.2.1 Vermiculite
The fire's vermiculite plates are located on the bottom and against the rear wall of the appliance
(see Annex 2, fig. 8). In the following situations the vermiculite plates must be taken out:
•
•
•
The bottom plates and the underlying felt are first removed and the rear plates last. The insertion of the
vermiculite plates takes place in reverse order.
Make sure that the vermiculite plates are placed back in the original position! The back plate, for instance, must be
!Caution
placed with the small, not countersunk, holes towards the front.
42
Do not fasten the bolts too tight to avoid breaking off and/or stripping: overtightening will cause breakage.
Place the glass pane (including new pane seal) with the logo to the bottom right.
Place a new door seal.
Slide both ends of the door seal in the supplied sleeve (see Annex 2, fig. 11).
When disassembling the air slide valve.
To be able to reach the adjustable legs.
When replacing the vermiculite plates.
I N S T A L LA T I ON M A N U A L