WATERTOEVOER SPECIFICATIES
Any damage caused by using water with parameters that do not
correspond to what is specified in this section is not covered by the
warranty*.
Het toegevoerde water moet:
- een maximumtemperatuur van 30°c hebben;
- drinkbaar zijn;
- een druk in het bereik van 150 en 600 kPa hebben (200 kPa is aanbevolen).
If the pressure of the water supply at the inlet is too low (below
150kPa), a pump with a suitable flow rate should be used (minimum
flow rate of 300 l/h). The BAKERLUX SHOP.Pro™ ovens come with
an integrated pressure reducer as standard.
WATER SPECIFICATIONS FOR THE STEAM CIRCUIT (STEAM INSIDE THE
OVEN CAVITY)
Free chlorine ≤ 0.1 ppm
Chloramines ≤ 0.1 ppm (mg/L)
TDS ≤ 125 ppm
Silica ≤ 12 ppm
pH 7 to 8.5
Total hardness (TH) ≤ 8 °d
Chlorides ≤ 25 ppm
Alkalinity ≤ 150 ppm as CaCO
* The maximum chloride content, Cl-, is not a fixed value; it depends on the calculated
Non Hardness Measurement (NHM)
NHM = EC - (TH** x 30)
EC = electrical conductivity [μS/cm]
TH = total hardness** [° dH - German degrees]
NHM ≤ 250 μS/cm
NHM = 250 - 350 μS/cm
NHM = 350 – 450 μS/cm
NHM = 450 – 500 μS/cm
NHM ≥ 500 μS/cm
* use the reagent in the UNOX KSTR1081A kit
** hardness measured using the UNOX KSTR1082A kit
*
Bezoek de Garantie sectie van de Unox-website (www.unox.com) voor meer informatie
24
3
TH < 8 °dH, Cl- ≤ 25 ppm (5 drops of
reagent*)
TH ≥ 8 °dH, Cl- ≤ 25 ppm (5 drops of
reagent*)
Cl- > 25 ppm (5 drops of reagent*)
Cl- ≤ 20 ppm (4 drops of reagent*)
Cl- > 20 ppm (4 drops of reagent*)
Cl- ≤ 15 ppm (3 drops of reagent*)
Cl- > 15 ppm (3 drops of reagent*)
Cl- ≤ 10 ppm (2 drops of reagent*)
Cl- > 10 ppm (2 drops of reagent*)
No water treatment
UNOX.Pure
UNOX.Pure-RO
UNOX.Pure
UNOX.Pure-RO
UNOX.Pure
UNOX.Pure-RO
UNOX.Pure
UNOX.Pure-RO
UNOX.Pure-RO