ADAPTING TO DIFFERENT VOLTAGE
For electrical and voltage requirements that differ from standard values,
it is necessary to replace the power supply cable (see the chapter "Some
stacking examples" on page. 22) and connect the new cable to the
terminal board following the diagrams on the "Technical specifications"
sheet (Power supply - Connection Diagram) attached to the appliance.
REPLACING THE POWER SUPPLY CABLE
The cable must be replaced by UNOX or by its technical assistance
service, or in all cases by a person with a similar role in order to
prevent any risks.
Follow the procedures below to replace the power supply cable:
- remove the rear panel of the oven and remove the cable by detaching it
from the terminal block;
- See the "Technical data sheet" (Power supply-Connection Diagram) on
the sheet indicates all possible wiring diagrams and the specifications
that the new cable must have in reference to the wiring selected (Cable
Type);
- secure the new cable using the cable clamp;
- close the rear panel of the oven.
22