firm click. The ceiling unit will now remain suspended in place.
Drehen Sie die vier Klemmschrauben von Hand fest, um die Deckeneinheit endgültig zu befestigen. Achtung: drü-
5
cken Sie dabei die Dunsthaube nicht nach oben und ziehen Sie die Halteklammern nicht zu stark an, da sie sich sonst
unnötig verbiegen. Sobald diese Klemmschrauben festgedreht sind, ist die Deckeneinheit einsatzbereit.
Removing the ceiling unit
6
Before dismounting, protect the cooking plate, for example using cardboard or cloth, in case a screw or clamp is
dropped onto it. To remove the ceiling unit, the 4 clamping screws have to be fully loosened. When these are loose,
the ceiling unit can be taken down. Watch out: the loosened clamping springs may drop down.
Remote installation of the motor unit
Take the motor unit from the ceiling unit by removing the 8 mounting screws (see (2)); use these screws again to
7
mount the tube adapter to the ceiling unit. You can loosen the plugs on the motor unit.
These are the possibilities of the positions the motor unit may occupy.
8
A Determine the location and the suspension position of the motor unit. If necessary, the exhaust direction of the
9
motor can be changed. The supply and exhaust pipes can be made in a 90° angle or opposite each other. TAKE
CARE: make sure the motor shaft is horizontal at all times!
B Screw the tube adapter (6830029) to the bottom of the motor using the screws (8x906151).
Mount the suspension bracket to the motor housing. This is done by first unscrewing the screws provided from the
10
motor housing. After this, place the suspension bracket onto the motor unit and screw it back on using the same
screws. You can choose position A or position B.
To mount the motor unit onto the wall, you first mark out the 4 drilling holes.
11
To mount onto a stone wall: use the screws 906055 and the plugs 906143.
12
- Drill the 4 marked-out points and place the plugs into the holes.
- Partly screw in 2 screws in position 1 and position 2.
- Suspend the motor unit over these 2 screws. Next, tighten the screws.
- Now screw in the screws in position 3 and position 4.
To mount onto a wooden wall: use the screws 906192.
- Partly screw in 2 screws in position 1 and position 2.
- Suspend the motor unit over these 2 screws. Next, tighten the screws.
- Now screw in the screws in position 3 and position 4.
Connect the plastic exhaust (864006) onto the tube adapter using 4 screws (906151).
13
Mount the suction and exhaust pipe to the motor unit by means of a hose clamp. Connect the plug of the cable co-
14
ming from the ceiling unit to the plug on the motor unit.
INSTALL THE EXHAUST DUCT
The exhaust of the hood must be properly taken care of. For optimum performance of the hood it is important to pay
attention to the following items during the installation:
• Use smooth, non-flammable pipes with an internal diameter that is equal to the external diameter of the connection
nozzle of the hood. Maximally extend flexible ducts and cut them to size.
• Do not reduce the exhaust diameter. This will lower the capacity and raise the noise level.
• Make the duct as short as possible and with as few as possible bends to the outside.
• Avoid square bends. Use rounded bends for proper air conduction.
• Flat duct: the surface of a flat duct must be the same size as Ø150 mm = 177 cm².
• In case of an exhaust pipe through the outside wall passing a cavity wall, make sure that the exhaust duct fully bridges
the cavity and slightly declines to the outside.
• When connecting to a short exhaust duct, it may be required to mount a non-return valve in the duct to avoid wind-
blowing in.
• Use a hose clamp or aluminum tape for airtight connections.
• In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
EN 14