9.2 Interior lining
9.2.1 Vermiculite
The fire's vermiculite plates are located on the bottom and against the rear and side walls of the appliance
(see appendix 2, fig. 4).
In the following situations the vermiculite plates must be taken out:
•
•
The bottom plates are removed first and the rear plates are removed last.
The insertion of the vermiculite plates takes place in reverse order.
Make sure that the vermiculite plates are placed back in their original position! The back plate, for instance, must
!Caution
be placed with the small, not countersunk, holes towards the front.
9.2.2 Flame baffle plates
At delivery the flame baffle plates are located at the top of the appliance.
In case of maintenance of the appliance, the flame baffle plates must be removed.
When removing the lower flame baffle plate, please proceed as follows (see appendix 2, fig. 5):
Ø
Take hold of the lower flame baffle plate and push the right side upwards.
Ø
Slide the lower flame baffle plate over the ridge to the right.
Ø
Lower the left side of the lower flame baffle plate and remove the lower flame baffle plate.
When removing the upper flame baffle plate, please proceed as follows (see appendix 2, fig. 5):
Ø
Lift the upper flame baffle plate from the ridge.
Ø
Move the bottom side of the upper baffle plate towards you.
Ø
Lower the upper flame baffle plate and remove it.
Placing the flame baffle plates takes place in reverse order.
•
!Caution
•
UK
When disassembling the air slide valve (see chapter 9.1.1).
When replacing the vermiculite plates.
Place the upper flame baffle plate in the centre between the two upright lips.
The stainless steel profile of the lower flame baffle plate must be placed at the front with the screw heads on
top (see appendix 2, fig. 6).