7.3.16 16-** Data-uitlezingen

Par.
Parameterbeschrijving
nr.
16-0* Alg. status
16-00
Stuurwoord
16-01
Referentie [Eenh.]
16-02
Referentie %
16-03
Statuswoord
16-05
Vrnste huid. waarde [%]
16-09
Standaard uitlez.
16-1* Motorstatus
16-10
Verm. [kW]
16-11
Verm. [pk]
16-12
Motorspanning
16-13
Frequentie
16-14
Motorstroom
16-15
Frequentie [%]
16-16
Koppel [Nm]
16-17
Snelh. [RPM]
16-18
Motor therm.
16-22
Koppel [%]
16-26
Verm. gefilterd [kW]
16-27
Verm. gefilterd [pk]
16-3* Status omvormer
16-30
DC-aansluitsp.
16-32
Remenergie/s
16-33
Remenergie/2 min.
16-34
Temp. koellich.
16-35
Inverter therm.
16-36
Inv. nom. stroom
16-37
Inv. max. stroom
16-38
SL-controllerstatus
16-39
Temp. stuurkaart
16-40
Logbuffer vol
16-43
Timed Actions Status
16-49
Current Fault Source
16-5* Ref. & terugk.
16-50
Externe referentie
16-52
Terugk. [Eenh]
16-53
Digi Pot referentie
16-54
Terugk. 1 [Eenh]
16-55
Terugk. 2 [Eenh]
16-56
Terugk. 3 [Eenh]
16-58
PID-uitgang [%]
®
VLT
HVAC Drive Bedieningshandleiding
Standaardwaarde
0 N/A
0.000 ReferenceFeedbackUnit
0.0 %
0 N/A
0.00 %
0.00 CustomReadoutUnit
0.00 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.00 %
0.0 Nm
0 RPM
0 %
0 %
0.000 kW
0.000 hp
0.000 kW
0.000 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] Nee
[0] Timed Actions Auto
0 N/A
0.0 N/A
0.000 ProcessCtrlUnit
0.00 N/A
0.000 ProcessCtrlUnit
0.000 ProcessCtrlUnit
0.000 ProcessCtrlUnit
0.0 %
®
MG.11.AD.18 –- VLT
is a gedeponeerd handelsmerk van Danfoss
4-set-up
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
0 V
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
Wijzigen
Conver-
Type
tijdens
sie-index
bedrijf
FALSE
0
V2
FALSE
-3
Int32
FALSE
-1
Int16
FALSE
0
V2
FALSE
-2
N2
FALSE
-2
Int32
FALSE
1
Int32
FALSE
-2
Int32
FALSE
-1
Uint16
FALSE
-1
Uint16
FALSE
-2
Int32
FALSE
-2
N2
FALSE
-1
Int32
FALSE
67
Int32
FALSE
0
Uint8
FALSE
0
Int16
FALSE
0
Int32
FALSE
-3
Int32
FALSE
0
Uint16
FALSE
0
Uint32
FALSE
0
Uint32
FALSE
100
Uint8
FALSE
0
Uint8
FALSE
-2
Uint32
FALSE
-2
Uint32
FALSE
0
Uint8
FALSE
100
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
0
Uint8
FALSE
-1
Int16
FALSE
-3
Int32
FALSE
-2
Int16
FALSE
-3
Int32
FALSE
-3
Int32
FALSE
-3
Int32
TRUE