Fault
Display shows "Please
fill water tank." despite
the fact that the water
tank is full.
Display shows "E61:
Please clean brewing
unit.".
Display shows "Incor-
rect voltage".
Display shows "Re-
start appliance".
Display shows
calc'nClean very fre-
quently.
Cause and troubleshooting
Insert a new water filter.
Limescale deposits in the water tank are blocking the
system.
Clean the water tank thoroughly.
1.
Start the descaling programme.
2.
Brewing unit is soiled.
Clean the brewing unit.
Mechanism of brewing unit is stiff.
Clean the brewing unit.
There are problems with the power supply.
Only operate the appliance at 220 - 240 V.
Appliance has a fault.
Set the mains switch to
1.
Set the mains switch to ⁠ .
2.
Decalcified water still contains small amounts of lime.
Insert a new water filter.
1.
Set the corresponding water hardness.
2.
Incorrect or too little descaling agent used.
When descaling, only use suitable tablets.
Service programme has not been carried out in its en-
tirety.
Start the "Special rinsing" service programme.
→ "Service programmes", Page 63
Troubleshooting en
and wait 60 seconds.
69