Parameter menu
° F
Fahrenheit
Password (lock function)
After switching the lock function on, only the fixed
temperature keys can be operated on the solde-
ring station. All other settings are disabled until the
repair station is unlocked again.
Notice
If you want only one temperature value to be
selectable, the control keys fixed temperature
keys) must be set to the same temperature value.
Lock the soldering station:
Set the required three-character locking code (bet-
ween 001-999) with the turn-and-click wheel.
The lock is active (the display shows a lock
symbol).
Vacuum pre-feed WXD 2 only
In order to prevent the pump from starting pre-
maturely or to ensure a defined soldering-joint
preheating time, it is possible to set an ON delay.
Vacuum run-on (WXD 2 only)
To prevent the desoldering iron from becoming
clogged, it is possible to set a vacuum run-on time.

Touchtones on/off

Option
Description
ON
On
36
All manuals and user guides at all-guides.com
Unlocking the soldering station
1. Call up the parameter menu. If the lock function
2. Set the three-character locking code using the
3. Confirm the code with the Enter key.
Forgotten code?
Please contact our Customer
Service: technical-service@
weller-tools.com
Option Description
0 sec
1-10
sec
Option Description
0 sec
1-10
sec
Open Menu
is active, the password menu item opens
automatically. Three stars (***) are shown on
the display.
turn-and-click wheel.
Open Menu
OFF: vacuum pre-feed function is OFF
(factory setting)
ON: vacuum pre-feed time, individually
Open Menu
OFF: vacuum run-on function is OFF
(factory setting)
ON: vacuum run-on time, individually
adjustable