Parameter menu
Standby Temp.
Note The soldering tools have a usage detector
(sensor) in the handle which automatically starts
the cooling cycle when the soldering tool is not in
use.
Standby time (temperature deactivation)
When the soldering tool is not in use, the tem-
perature is reduced to Standby temperature on
expiration of the set Standby time. The display
reads „Standby".
Press control key to exit Standby mode. The
sensor integrated tool detects the change in state
and deactivates Standby mode as soon as the tool
is moved.
AUTO OFF time (automatic switch-off time)
When the soldering tool is not in use, the soldering
tool heater is switched off when the AUTO OFF
time expires.
Temperature deactivation is performed indepen-
dently of the set standby function. The actual
temperature is indicated by flashing LED and
serves as a residual heat display. The display
reads „OFF".
Sensitivity
Option
Description
Low
Non-Sensitive – Reacts to heavy (long) movement
Normal
Standard (factory setting)
High
Sensitive - Reacts to light (short) movement
---
The tool is not supported
Max. hot air duration WXHAP 200
The on-time of the hot air flow of the WXHAP 200
can be limited in increments of 1 to between 0 and
300 sec. The factory default is 0 s („OFF"), i.e. air
flows only as long as the button on the hot air tool
or the optional footswitch is pressed.
34
All manuals and user guides at all-guides.com
The standby temperature is automatically set after
a temperature deactivation.
Option
OFF
1-999 min standby time, individually adjustable
---
Option
OFF
1-999 min AUTO-OFF time, can be set indivi-
Option
OFF
1-300 s
Menu access
Tool parameters
Menu access
Tool parameters
Description
standby time is deactivated (factory
setting)
The tool is not supported
Menu access
Tool parameters
Description
AUTO OFF function is deactivated
(factory setting)
dually.
Menu access
Tool parameters
Open Menu
Tool parameters
Description
No duration defined
(factory setting)
Individually adjustable