WARNING NOTICE
S A N I C O M
®
is a lifting pump for wastewater used in commercial
applications (restaurants, hairdressing salons, the catering
industry etc.). The unit operates automatically, has a high
performance level, and is safe and reliable, provided all the
rules for installation and maintenance in this notice are
strictly followed.
Especially those indicated by:
"
" Failure to comply with this instruction could endanger
the safety of persons,
"
" Indication that a risk of electrical
origin exists,
"
" Electrical installation must be carried out by a
professional electrician.
"AT T E N T I O
N" Failure to comply with this instruction could
endanger the safe functioning of the apparatus.
For any additional information, please contact our customer
service department.
HOW IT WORKS
S A N I C O M
®
contains 1 pump. The tank is equipped with a
sensor tube which controls the automatic activation of the motor
when waste enters the unit.
As soon as the waste enters the tank, the pump starts.
2
LIST OF PARTS SUPPLIED
3
D I M E N S I O N S
4
S A N I C O M
®
TECHNICAL DATA AND APPLICAT I O N
Application
Type
Maximum vertical pumping height
Voltage
Frequency
Maximum power consumption
Maximum current consumption
Electrical class
Protection index
Max temp with intermittent functioning
Net weight
* In the case of bath or shower tray, make sure the waste
traps are raised 15 cm above floor level.
CAUTION: 1. All applications other than those described in
this notice are prohibited.
2. Do not exceed an incoming flow rate greater
than 80% of the flow rate stated on the design
curve
5
in any of the apparatus.
5
PERFORMANCE CURV E S
6
VERTICAL/HORIZONTAL PUMPING
7
I N S TA L L AT I O N
The pump has securing devices, preventing it from turning
or moving.
7a
F I T T I N G
1- Warning: The space in which S A N I C O M
be large enough to leave at least 600mm around the unit for
easy maintenance. This space must be well lit,ventilated,
and must never be immersed in water and must be
protected from frost.
Sinks, washing machine,
dishwasher or shower*
or bath*
FF03-P95
8 m
220 – 240 V
50 Hz
750 W
3.3 A
I
IP44
80°
10 kg
®
is installed must
2- Isolation valves should be fitted to the inlet pipework and
discharge pipework to isolate the unit in case of the need
for service.
3- This evacuation pipe must be designed so as to prevent
back-flow from the sewers.
CONNECTION TO SIDE INLETS
7b
Use the flexible inlet connector
Using a metalwork saw, saw
the desired input point, remove any burrs and then fix the
flexible inlet connector with the jubilee clip
CAUTION:
In the case of an installation for drainage of
greasy wastes allow for a grease trap in front of each input
point.
Connection to the inlet can be made using a DN40
or DN50 pipe. To make a DN50 connection, cut off the end
A
of sleeve
beforehand.
CONNECTION TO SANITARY WARE
7c
To connect bathtub (or shower), make sure the waste trap
height is raised by at least 15 cm above floor level.
Connection must be made using 40 mm or 50 mm diameter
pipework, with minimum slope of 1%.
CONNECTION TO SOIL AND VENT PIPE OR DRAIN
7d
The disposal of waste from the SANICOM
through a 32 mm diameter copper or plastic pipes (or PVC,
ABS, etc.).
Horizontal discharge pipework should maintain a 1% fall
(1cm/M) to the soil and vent pipe. If a vertical rise is
required, this must be installed at the start of the run,
before the horizontal section.
Take care that the discharge valve flap faces the direction
of flow.
If the end of the discharge pipework is much lower than the
unit, install a riser pipe about 80mm long from the highest
point of the discharge run and fit an air admittance pipe on
top (capable of withstanding at least 15psi pressure.) to
break the syphon.
End the outlet pipe at the waste stack.
7e
IN CASE SERVICE IS NEEDED
Allow for a drain-off point at the bottom of the rising waste
pipe. Ensure that the unit is easily accessible for possible
maintenance.
7f
ELECTRICAL CONNECTION
Electrical installation must be carried out by a professional
e l e c t r i c i a n .
Supply must be class 1. The device must be connected to a
d i fferential circuit breaker calibrated to 30mA and protected by
a 10A fuse. This connection must be used exclusively for
supplying the SANICOM
®
u n i t .
Installation and use of this unit must conform to the standards
applicable in the country of use:
E.g.
• France: NFC-100 standards
• Germany: VDE 0100
For any work on the electrical parts of the apparatus,
contact an approved Saniflo engineer.
CAUTION:
When the apparatus is connected up for the first
time, it will work for 5 seconds even if there is no water in
the basin. This operation acts as a manual start-up.