Equipotential bonding

Carrying out a firmware update

Note
The station must not be
switched off while the firmware
update is running.

Connecting auxiliary devices

Please observe the overview diagrams.
Connecting auxiliary devices
Auxiliary devices can be connected either to the port on the front panel and/or to the port on the back of
the Soldering Station.
The Soldering Station detects automatically which auxiliary device is connected. The Soldering Station
shows the symbol or name of the connected auxiliary device on the front port or rear port.
Setting the parameters of auxiliary devices
auf
1. Select the auxiliary device using the auxiliary device key (front/back).
dere
The variable parameters (e.g. speed) are displayed.
2. Set the required value using the turn-and-click wheel.
3. Confirm the value with the Enter key

Care and maintenance

Clean the operator panel, if dirty, using a suitable cleaning cloth.
Seal ports which are not in use with covering caps.
36
All manuals and user guides at all-guides.com
Four variants are possible by connecting the 3.5 mm jack socket
differently:
a
a
Hard-grounded
b
b
Equipotential
bonding
c
c
Floating
d
Soft-grounded
d
1. Switch off the Soldering Station.
2. Insert the memory stick into the USB port.
3. Switch on the Soldering Station.
The firmware update is performed automatically.
If you have a more already installed more recent firmware on your
station, this will not be changed.
supplied without plug.
with plug, equaliser at centre contact.
with plug
with plug and soldered resistor. Ground-
ed through selected resistor.