Increase the temperature measured by the ambient temperature sensor
by 2°C by pressing
.
In our example the measured temperature by the sensor goes
from 21°C to 23°C.
To validate the new value press
3 times.
The reset to zero of the sensor calibration
To put the value of the correction to "0", do the following :
1- When the temperature measured by the sensor appears, press
for at least 3 seconds.
2- To save and move automatically to the next setting press
exit the Expert settings, press
Important:
These changes should be performed by a qualifi ed
staff , it should be performed in production or on site during the
fi rst installation

SETTING THE ENERGY TYPE

Our blower can be used to manage 2 types of energy:
- The electric energy provided by the home electric installation to control
an electric towel rails.
Or
- The hot water provided by the heat generator of the central heating
installation to control an hydraulic towel rails. In this case, the blower
will manage a motorized valve installed on the towel rails.
By default, the blower has been confi gurated to control an electrical
towel rails.
ELEC
1-
appears on the display. By pressing
change the energy type used by the towel rails.
M16MI328 A01_01/18
. To exit the Expert settings, press
3 sec.
3 times.
or
, you can
ELEC
= electric energy
HYdr
= hydraulic energy
2- To save and move automatically to the next setting press
To exit the Expert settings, press

SETTING THE POWER

To have a controller adapted to the towel rails and estimate the energy
consumed, it is essantial to set the power of the device.
1- Pre set value: 500W. Select a value between 500W and 1500W by
pressing
or
or
2- To save and move automatically to the next setting press
. To
3- To exit the Expert settings, press

INTERNAL TEMPERATURE MONITORING

An integrated overheating safety is present on our blower. It is acti-
vated when an internal temperature limit is reached: the blower and its
controller will stop immediately.
The maximum setting is preset to 65°C. You can adjust from 60°C to
90°C by intervals of 5°C.
Press
or
then save by pressing
If you do not want to change it, press
tically to set the next setting.
To exit the Expert settings, press
3 times.
.