INSTALLER SETTINGS
ACCESS
You access to User settings in 4 steps:
From Auto, Comfort, Eco or Frost protection mode :
Information display
1
1
Press for 5
seconds
Setting sequence:
Confi guration of detection modes
CONFIGURATION OF DETECTION MODES
Open window detection, activation/ deactivation of the
Auto mode
The automatic mode enabled is the default setting.
1- Press
or
.
On
= automatic mode enabled.
OFF
= automatic mode disabled.
2- To save and move automatically to the next setting, press
exit the user settings, press
Occupancy detection, activation/deactivation
1- The occupancy detection enabled is the default setting.
M16MI328 A02_01/18
Information displays
2
Press briefl y
twice
Dual optimization feature
3 times.
3
1
Press for 10
seconds
Super Comfort
PIN code lock
2- Press
or
.
ON
= occupancy detection enabled.
OFF
= occupancy detection disabled.
3- To save and move automatically to the next setting, press
exit the user settings, press
DUAL OPTIMIZATION FEATURE
This feature is available on the device equipped with a occupancy de-
tector.
Overview
- Dual function optimization, priority to comfort or energy savings,
the choice is yours: Depending on various parameters: room inertia,
ambient temperature, desired temperature, the device calculates and
optimizes the programming for each heating period whether set to
Comfort or Savings (Eco):
. To
- In OPTI ECO mode (effi ciency priority), the devices inbuilt algorythmes
will calculate the best compromise in order to guarantee maximum
energy savings throughout the programmed increase and decrease
phases.
In this mode, a slight drop in the temperature level at the beginning
and end of the comfort period is allowed to maximize energy savings.
- In OPTI COMFORT mode (priority to comfort), the device intelligence
calculates the best compromise in order to guarantee maximum
comfort during the programmed increase and decrease phases.
In OPTI COMFORT mode, the priority is given to anticipating and
maintaining the comfort temperature during periods of detected oc-
cupancy.
InSt
4
= Installer
settings
Press briefl y
Restoring factory settings
5 sec.
3 times.
. To
16