USER SETTINGS
ACCESS
You access to User settings in 3 steps:
From Auto, Comfort, Eco or Frost protection mode :
Information display
1
1
Press for 5
seconds
Setting sequence:
Backlighting
Eco mode temperature lowering-level
Maximal Boost duration
BACKLIGHT SETTING
1- Three modes can be set:
Version without occupancy detector:
L1
= Temporary backlighting: Backlight of the display when a but-
ton is pressed.
L2
= Non-stop backlighting: Backlight of the display all the time.
L3
= In this version, the device will work according to the L1 mode.
Version with occupancy detector:
L1
= Temporary backlighting: Backlight of the display when a but-
ton is pressed or during occupancy detection.
L2
= Non-stop backlighting: Backlight of the display all the time.
L3
= Temporary backlighting: Backlight of the display when a but-
ton is pressed.
L3 mode is the default setting.
Press
or
to choose the setting you require.
2- Press
to save and move to the next setting.
To exit the user settings, press
2
Press briefl y
twice
Frost protection temperature
Maximum ambient temperature
twice.
Information display
1
Super comfort
Temperature unit
SETTING THE ECO MODE TEMPERATURE
LOWERING-LEVEL
The drop in temperature is set at -3.5°C compared to the set tempera-
ture of the Comfort mode. You can adjust the lowered level from -1°C to
-8°C, by intervals of 0.5°C.
Important: whatever the lowering level set, the Eco setting temperature
will never exceed 19°C.
3- Press
or
to obtain the temperature level you require.
4- Press
to save and move to the next setting.
To exit the user settings, press
SETTING THE FROST PROTECTION
TEMPERATURE
Your device is preset at 7°C. You can adjust the Frost protection
temperature from 5°C to 15°C, by intevals of 0.5°C.
5- Press
or
to obtain the temperature you require.
6- Press
to save and move to the next setting.
To exit the user settings, press
User
= user settings
Comfort setting temperature limit
twice.
twice.
M16MI328 A02_01/18
3
Press briefl y
13