No.
Description
1
Negative terminal connection with a cable cross-section of 1.5 mm²
2
Positive terminal connection of the house battery 1
3
Positive terminal connection for RV devices
4
Positive terminal connection of the house battery 2
5
Remote control connection
8
Operation
Disconnecting the batteries
1. Press the selection button for 5 s.
The house batteries are disconnected from the split charge relay.
NOTE The batteries are automatically replaced as a power source when a power source, e.g.,
an alternator, is detected.
2. Press the selection button for 2 s to reconnect the house batteries.
The red LED lights up continuously, the manual mode is activated, and the house battery 1 is selected for
operation.