5.3

Positions of the Ecolift FKA emergency closure lever

Position
Function
"OPEN"
Operating posi-
(lever in
tion
sewer-side
position)
„N"
Construction
(lever in cen-
phase position,
tral position)
pendulum posi-
tion
"CLOSED"
Pipe locking in
(lever in
the event of a
house-side
breakdown or
position)
decommission-
ing
016-319
Effect
The consumers connected can be drained and are
secured by the motor-driven backwater flap.
The consumers connected can be drained and are
secured against backwater by a flap. This non-
motor-driven condition as supplied is only suitable
for the drainage of faecal-free wastewater (e.g. dur-
ing the construction phase until commissioning has
taken place properly).
The building is secured in the best possible way
against water penetration; the consumers can be
drained.